Euromatic PQ81A Instruction Manual Download Page 16

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

1     2    3     4

ON          ECE

14 

SWITCH  SW2

dip n° 1

dip n° 2

dip n° 3

dip n° 4

ON

OFF

 = 

Ram blow and closing thrust DEACTIVATED

 

ON

  = 

Ram blow and closing thrust ACTIVATED 

(just for gates with electrolock) 

OFF

ON

OFF

 = 

Photocell in OPENING ACTIVATED

 

ON

  = 

Mechanical safety edge ACTIVATED          

           8K2 resistive safety edge ACTIVATED. 

N.B.: It’s mandatory to carry out the INPUT TEST

OFF

ON

OFF

 = 

Immediate closing mode DEACTIVATED

ON

  = 

Immediate closing mode ACTIVATED 

           

The gate starts CLOSING after 1,5 sec. 

           bypassing the AUTOMATIC CLOSING COUNT DOWN

OFF

ON

OFF

 = 

Ram stroke RELEASE mode DEACTIVATED

ON

  = 

Ram stroke RELEASE mode ACTIVATED 

           At the endpoint stage during CLOSING and OPENING, the motors press onto the mechanical 

             endstop, cut the thrust, and release a small space between the doors for safety operation.

OFF

Summary of Contents for PQ81A

Page 1: ...movable radio receiver 433 92 MHz 32 codes suitable for fixed or rolling code transmitters Input for 8K2 resistive safety edge Self diagnosis of malfunctions by LED coding 230Vac TECHNICAL FEATURES It...

Page 2: ...dio channel pag 11 3 10 2 Signalling light 3 10 3 CCourtesy light 4 DEFAULT SETTINGS pag 12 5 BROWSING THE MENU 5 1 FUNCTIONS MENU 5 1 1 Automatic closing 5 1 2 8K2 resistive safety edge input just in...

Page 3: ...ly wired Wiring installation and functional tests must be carried out by expert qualified personnel in full compliance with current regulation EN12453 Use of this control panel must be restricted to t...

Page 4: ...4V 0 6A V1 varistor secondary K2 K3 motors rel K4 flashing light rel TR2 filter JP1 GREEN TERMINAL aerial connection JP2 Secondary MOLEX card 24V ac JP3 Primary MOLEX card 230V ac JP4 BLUE TERMINAL co...

Page 5: ...CLOSE CAPACITOR CAPACITOR FLASHING LIGTH 24V ac MAX 20w PEDESTRIAN STOP START NEUTRAL CLOSING PHOTOCELL OPENING PHOTOCELL PHOTOCELL CLOSING PHOTOCELL OPENING 24V RX 24V TX RX TRANSFORMER 230V 21V RED...

Page 6: ...photocells 5 5 photocell in closing N C contact 6 photocell in opening N C contact 7 RX photocells 24V 8 TX RX 24V 9 TX photocells 24V JP6 YELLOW TERMINAL flashing light 10 flashing light 24V ac max...

Page 7: ...M1 Brown Grey Blue Brown Black Grey Blue Black CAPACITOR Left leaf M1 Right leaf M1 Brown Grey Blue Brown Black Grey Blue Black CAPACITOR Grey Blue Brown Black CAPACITOR Grey Blue Brown Black CAPACIT...

Page 8: ...o 3 4 terminal JP4 An additional PEDESTRIAN START contact can be wired in PARALLEL N O contact 3 3 1 TIMER It is possible to wire a TIMER N O contact to 1 4 terminal JP4 WARNING when connecting a TIME...

Page 9: ...5 and 9 together 3 6 2 Photocells in OPENING Feed the photocells through 7 8 9 terminal JP5 Wire the photocell contact N C contact to 6 7 terminal JP5 An additional photocell set can be wired in SERIE...

Page 10: ...l in series If the contact is broken during CLOSING the gate stops and reverses If the contact is broken during OPENING the gate keeps on working normally 3 7 2 Mechanical safety edge in OPENING Wire...

Page 11: ...inal JP5 If the contact is broken during OPENING the gate stops and reverses after 3 sec If the beam is broken during CLOSING the gate stops and reverses 8K2 safety edge photocells in OPENING Adjust S...

Page 12: ...10 Electrolock 12V max 15W MEL04 Interface MRX01 Interface HOW TO PLUG THE 2nd RADIO CHANNEL INTERFACE slidewey ATTENTION CUT THE POWER OFF BEFORE PLUGGING THE JACK Plug the MRX01 jack optional onto c...

Page 13: ...ON 3 OFF 4 NO EFFECT TIMED COMMAND IThe contact ACTIVATES when giving a start command by the remote control and stays for 90 seconds If you wish to choose this function mode select the switches as fo...

Page 14: ...arts the count down Press BREAK again when reached the desired time the blinker turns off The time has been set automatic closing time max 120 sec To desactivate the AUTOMATIC CLOSING Press SET for 3...

Page 15: ...riority to the first open command The control unit won t accept additional START commands during OPENING and AUTOMATIC CLOSING COUNT DOWN dip n 3 dip n 4 OFF Double leaf gate mode ON Single leaf gate...

Page 16: ...nical safety edge ACTIVATED 8K2 resistive safety edge ACTIVATED N B It s mandatory to carry out the INPUT TEST OFF ON OFF Immediate closing mode DEACTIVATED ON Immediate closing mode ACTIVATED The gat...

Page 17: ...ISTING RADIO CODES Press SET TX and keep pressed for 10 seconds DL1 blinks DL1 turns off All codes have been deleted 7 2 LOADING A REMOTE CONTROL AS START COMMAND Press SET TX once DL1 blinks 1 blink...

Page 18: ...he ground mechanical endstop in closing At this stage the gate performs an OPENING RUN until fully open and a CLOSING RUN until fully close When the procedure is finished all time settings are saved T...

Page 19: ...When motor starts working release SET Motor runs firstly a short OPENING for 4 sec M1 first and M2 after delayed leaf then CLOSE until the ground mechanical endstop in closing At this stage the gate...

Page 20: ...fully open let the motor run for 3 4 sec then press the remote control Now M2 settings are LOADED Press the remote control M2 motor STARTS CLOSING Press the remote control the control panel starts cou...

Page 21: ...Incorrect electric wiring Disconnected photocell Permanent PEDESTRIAN command SOLUTION Check the wiring and operation of the photocell Check the wiring and operation of the motors Check the connectio...

Reviews: