GB
22
– Press the
[
]
button, the unit would start to heat
up, press once time for low-level heating, the dis-
play would show
[
]
; press twice times for mid-
level heating, the display would show
[
]
; press
third times for high-level heating, the display
would show
[
]
[
]
; press fourth times for anit-
frost, the display would show
[
]
.
– Press the
[
]
timer button once, the display
would show
[00]
, and the
[
]
timer icon would
light up. If there is no operation, it would return to
the temperature display interface, and the
[
]
timer icon would go out, indicating that there is no
timer. To set the timer, press
[
▲
]
up button
and
[
▼
]
down button to select 0–24 hours timing.
When the timer is set, the
[
]
timer icon would
lights up.
– Press the
[°C]
temperature button once, the
default temperature 35 °C would be displayed
and flash. Press
[
▲
]
up button and
[
▼
]
down but-
ton to select the desired temperature. The tem-
perature can be adjusted from 0–50 °C. After
selecting the desired temperature, it would flash 5
times and return to the ambient temperature inter-
face.
Turbo function
– Press the
[ ]
button, the
[ ]
light would be on,
the fan would operate. Press the
[ ]
button
again, the
[ ]
light would be off, Turbo function is
turned off.
Safety equipment
This heater has two protection devices:
•
Thermal link: it would automatically disconnect
the power to the heater at the overheating tem-
perature. After cooling down, it would reset itself If
it happens, please check if there are any abnor-
malities causing overheat.
•
Thermal fuse: it would permanently disconnect
the heater in case of overheating. (Cannot be
reset).
Cleaning
– Switch off the device and let it cool off completely.
– Pull out the plug.
– Wipe the device with a slightly damp cloth.
Faults and remedial measures
When something isn’t working…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the ven-
dor. You will save yourself a lot of trouble and possibly
money too.
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
A crossed-out wheelie bin icon means: Bat-
teries and rechargeable batteries, electrical
or electronic devices must not be disposed of
with household waste. They may contain
substances that are harmful to the environ-
ment and human health.
Consumers must dispose of waste electrical devices,
spent portable batteries and rechargeable batteries
separately from household waste at an official collec-
tion point to ensure that these items are processed
correctly. Information on returning these items is
available from the seller. Sellers are required to
accept these items free of charge.
Batteries and rechargeable batteries, which
are not permanently installed in waste elec-
trical devices, must be removed prior to dis-
posal and must be disposed of separately.
Lithium batteries and battery packs in all systems
must only be retuned to a collection point when dis-
Note:
The heating icon
[ ]
will only light up
when the ambient temperature is lower than
the set temperature.
Note:
In anti-frost mode, the heater will
operate when the ambient temperature is
below 5 °C and it will turn off itself when the
ambient temperature is 7 °C or above.
Note:
The default temperature is 35 °C
Note:
The heater would heat up during use.
Appropriate precautions must be taken to
prevent burns, scalds, fire or other personal
injury hazards.
DANGER! Risk of injury!
Before all work
on the device, always disconnect the mains
plug.
DANGER! Risk of injury!
Improperly per-
formed repairs can lead to the device not
functioning safely. This endangers yourself
and your environment.
Fault/malfunc-
tion
Cause
Remedial measure
Device does not
heat.
Is the device switched off?
Switch on the device or set the desired heat
level.
Is the temperature regulator (3) set too low?
Set the temperature regulator higher.
No mains voltage?
Check cables, plugs, outlets and fuse.
Blower is not
working.
Is the blower not switched on?
Switch on blower.
No mains voltage?
Check cables, plugs, outlets and fuse.
Summary of Contents for 482178
Page 42: ...SI 42 Kontaktni podatki Euromate GmbH Emil Lux Stra e 1 42929 Wermelskirchen GERMANY...
Page 52: ...BA HR 52 podaci za kontakt Euromate GmbH Emil Lux Stra e 1 42929 Wermelskirchen GERMANY...
Page 53: ...RU 53 53 53 54 54 54 55 55 56 56 81 30...
Page 54: ...RU 54 75 8 3 3 8 3 8 3 1 2 3 1...
Page 55: ...RU 55 0 4 1 2 3 4 5 6 7 00 0 24 C 35 C 0 C 50 C 5 C 7 C 35 C 3...
Page 57: ...RU 57 elSB 0 0006 kW Euromate GmbH Emil Lux Stra e 1 42929 Wermelskirchen GERMANY...
Page 58: ...GR 58 58 58 59 59 60 60 60 61 61 85 FI 30 mA...
Page 59: ...GR 59 K 75 cm 8 K 3 3 8 3 8 K 3 x1 x2 3 1...
Page 60: ...GR 60 0 4 1 ON OFF 2 3 Turbo 4 5 6 7 00 0 24 C 35 C 0 C 50 C K 5 C 7 C 35 C...
Page 76: ...KAZ 76 76 76 77 77 77 78 78 79 79 86 30 I...
Page 77: ...KAZ 77 75 8 3 3 8 3 8 3 1 2 3 0 1 I...
Page 78: ...KAZ 78 4 1 2 3 4 5 6 7 00 0 24 C 35 C 0 C 50 C 5 7 C 35 C I I 3...
Page 80: ...KAZ 80 Euromate GmbH Emil Lux Stra e 1 42929 Wermelskirchen GERMANY...
Page 81: ...81 RU 1 2 24 3...
Page 82: ...82 4 20 13109 97...
Page 87: ...87...