INLU90 Off Board Undercupboard Rangehood User Manual
Important points to consider for installation
1. The location of the fan unit shall allow access for maintenance and repair. Permanent fixed
means of access is required where the fan unit location is beyond the extent of normal steps or
ladders.
2. Before installation, please ensure the area is clean to avoid suction of the remaining bits of debris
and dust.
3. Please ensure that the fan motor is firmly secured to either a flat surface such as an MDF panel
affixed across the ceiling rafters, or fixed to the ceiling rafters themselves. Ensure the fan motor
is level and there is no vibration when in use.
4. The Rangehood cannot share the same air ventilation tube with other appliances such as gas
tube, warmer tube, and hot wind tube.
5. After installation, make sure that the main body is level to avoid grease collection at one end.
6. Please note the dimensions of the fan motor below for installation purposes.
7. The use of a ducting kit is imperative for the performance of the fan motor.
8. The bending of ducting tube should be ≥120°, parallel or above the start point and should be
connected to the external wall, roof or eave.
9. The recommended maximum lengths of ducting pipe should be no more than:
–
Four (4) metres for connection between the hood body and fan motor.
–
Three (3) metres for connection between the fan motor and outside.
The fan motor must be secured using the supplied bracket and screws
Correct
Incorrect