NOTE:
You must test the cooker after installation, before you hand it over to the customer. You must have a
manometer and a connecting tube.
Checking gas supply
• Check the manometer zero point is correct.
• Connect the manometer to the cooker pressure test point. This is located on the NG regulator or LPG inlet fitting.
• Turn on the gas supply and the electricity (if applicable) and try to ignite the gas.
NOTE:
It will take additional time to light the gas for the first time as air needs to be purged from the pipes.
• Check the operating pressure for the particular gas type (see table).
For LPG cookers
• Adjust or replace the regulator on the gas bottle if necessary (this may be remote from the cooker).
For Natural Gas cookers
• Regulators are supplied pre-adjusted and configured by the component maker for use with Natural Gas.
The appliance installer is not required to make an adjustment to obtain the correct outlet pressure setting.
• An arrow on the base of the regulator indicates the direction of gas flow when the inlet and outlet of
the regulator are orientated correctly. When the regulator has been fitted check for leaks from the
connections with soapy water.
Checking the Function of the Regulator
With the appliance operating check the outlet pressure:
• When all burners of the appliance are operating at maximum,
• When the smallest burner of the appliance is operating at minimum.
Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 1.0kPa by more
than ±20% of the nominal outlet pressure (±0.20kPa for Natural Gas).
If the regulator appears to not be performing satisfactorily then check the following points.
• If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an
upstream regulator may be needed, or an upstream regulator or valve with insufficient flow capacity may
be present in the gas supply line. If this is suspected then it may be necessary to repeat the checks whilst
measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1.13 – 5kPa.
• Check that the regulator has been fitted to the gas supply line in the correct orientation, the arrow on
the base of the body indicates the direction of gas flow. Once these checks have been completed, if
the regulator still fails to perform in a satisfactory manner it should be replaced.
Testing the cooker features
Observe the flame appearance on each burner. If it is much smaller or larger than expected, then the
injector size needs checking.
When maximum flame appearance is correct, then check the turn-down setting on each burner. If the
settings appear to be incorrect, proceed as follows:
• Adjust the bypass screw mounted on the body of each hotplate control cock. This is accessible when
the control knob and the control panel are removed.
• Check the ignition on all burners both separately and in combination.
• Check the operation of the electrical components, if applicable.
• If you are satisfied that the cooker is operating correctly, then turn it off and show the customer how to
use it. Make sure you ask the customer to operate the clock and controls.
NOTE:
If the cooker cannot be adjusted to perform correctly, then inform the customer of the problem and
put a warning notice on the cooker. If the problem is dangerous, then disconnect the cooker. If there is a fault,
then the customer should be advised to contact the manufacturer’s local service organisation or the retailer.