Gas Conversion (NG to ULPG)
If the required gas conversion kit is not supplied with your
appliance, contact Glen Dimplex. Gas Conversion shall
only be undertaken by authorised persons.
The NG to U-LPG conversion kit contains...
- Test Point Assembly
- U
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and
remove the jets, replacing them with those
supplied in this kit. Ensure you use the correct
jet for the corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied with this kit next
to the gas connection point and remove the
existing label.
Setting the minimum level
1. Light one of the burners and turn the tap to
minimum flame.
2. Remove the corresponding control knob.
3. Use a thin blade screwdriver to turn the by-pass
screw as shown right.
Turn the by-pass screw fully clockwise.The
result should be a small, stable flame which is
uniform around the entire burner ring. If not,
turn the by-pass screw anti-clockwise until
satisfied with the flame.
4. Check that the burner does not go out when the
tap is turned quickly from the maximum to the
minimum position.
5. Repeat for each burner.
LPG Gas Type label
24
-
Auxiliary Jet Ø0.53mm
-
Semi-Rapid Jet Ø0.70mm
-
Rapid Jet Ø0.90mm
-
5kw Dual Wok Jet
0.90mm, 0.46mm
-
4kW Wok Jet Ø1.00mm
Converting to a different gas type
When converting from Natural Gas to ULPG ensure that the NG
regulator is removed and replaced with the Test Point Assembly
supplied in this kit. An Australian Approved gas regulator suitable for a
supply pressure of 2.75kPa should be part of the gas tank supply and
the test point pressure must be adjusted to 2.75kPa.