LAMPO Multifunction Unit
4.8 START-UP
With machine stationary and stable, placed near the water basin, with stabilising feet on the ground and installed ground connection, follow the instructions below:
Before engine start-up, check that the service sockets are free and the circuit breakers are lowered to prevent sudden starts.
Never cover the machine during its operation.
Never place flammable materials (fuel, solvents, paper, etc.)
near the machine
With ground resistivity equal to 50, the plate must be fixed at a depth of 1.5
metres, thus ensuring the maximum safety.
>1.5 mt
For no reason the machine can be used without plate installed in the ground.
The incorrect grounding may lead to malfunctions of the machine electronic
components and make it potentially dangerous.
4.8.1 LAMPO VERSION - WITHOUT PUMP
DESCRIPTION
CIM-136
CEM-120
DESCRIPTION
CIM-136
CEM-120
1.
Make sure of machine stability and its
ground connection, turn the control unit on
using the “Control Unit OFF-ON” selector
(for version with CEM 120 only).
CONTROL UNIT
OFF ON
2.
Press “Function” key to select the manual
operation mode (MAN)
OFF
AUT
MAN
PROG
3.
Press “Start” button to start the engine
START
4.
Press “Pump protection disabling/
enabling” button to disable control unit
intervention for anomalies on working
pressure.
5.
Enable the auxiliary circuits from the
LAMPO command and control unit (Fig. 5.12)
(for version with CEM 120 only).
AUX
OFF ON
6.
Close the control panel door and remove
the key, to prevent access of unauthorised
personnel.
26