background image

EuroLuBE EQuipMEnt aB

Stråssavägen 2, SE-711 76 Storå, Sweden

EMAIL 

[email protected] 

PHONE 

+46 581 836 65 

FAX 

+46 581 409 75 

www.eurolube.com

part no 53419

DaLLaS KEY rEaDEr

2

MECHaniCaL inStaLLation

ConFiguration

First disconnect the keypad from the LUBE-Master system. Make 

1. 

sure that the keypad is not powered. 

Insert the 16-pin adapter into the 16-pin socket on the PCB of 

2. 

the keypad. Make sure that the adapter is oriented correctly and 
that all pegs are aligned before pressing it in place. The correct 
orientation is notch against notch. 
 

Drill a ø9.5mm hole at a convenient location on the keypad. Insert 

3. 

the reader probe into the hole. From the inside first add the plastic 
washer and then press the lock washer in place. 
 

Attach the 2-pole connector of the probe to the keyed 10-pole 

4. 

connector on the PCB of the keypad. Make sure that it is connected 
to the correct pins and that the colours are correct (Black/Grey)

Enabling the Dallas key reader for the keypad must be done from a PC running LUBE-
Master WinTools. To do this, select the Dallas Reader from the “Baudrate” selector in 
Keypad properties. 

Below is a sample for using the 9 last digits of the fixed serial number of a key as Job 
number input. 

After changing to “Dallas reader” reboot keypad. This is done either by quickly (less than 3 
seconds) press the Reset button or by power-down / power-up the keypad.

BLACK

GREY

Reviews: