Eurolube Equipment E80 Series Service Manual Download Page 1

www.eurolube.com

205128

  EUROLUBE EQUIPMENT 

PART NO 15740, 15741 & 15742 / ART.NR. 15740, 15741 & 15742

E80-sERiEs 15:1 OiL PUMP

SER

V

IC

E G

U

ID

E

2

0

1

7

-0

4

 O
R

IG

INAL

 MA

NU
AL

1

 General

Thank you for choosing a high quality Eurolube pump. 
The 15:1 high capacity oil pump features a unique air 
motor for quiet and quick serviceability. Recommended 
for large installations with long lengths of piping supplying 
several outlets simultaneously. Please refer to the sales 
catalogue for details on accessories. Or visit our website, 
www.eurolube.com. 
A pump’s ability to deliver fluid is based on the pressure 
(bar/psi) and quantity of air supplied to the air- motor and 
the amount of material discharge (back) pressure to be 
overcome within the system.

WARNING!

 

Do NOT use solvents or other explosive fluids. 

Never point a control valve at any portion of your body or 
another person. Accidential discharge of pressure and/
or material can result in injury. Read these instruction 
carefully before installation, operation or service.

 

DO NOT EXCEED MAXIUMUM PRESSURE

 

Allmänt

Tack för att ni valde en kvalitetspump från Eurolube. Vår 
högkapacitets 15:1 oljepump kännetecknas av låg ljudnivå 
och hög driftsäkerhet. Enkel att serva och med låg under-
hållskostnad. Utmärkt till applikationer där man behöver olja 
i långa rörledningar och med flera samtidiga tappningar. För 
detaljerad information hänvisar vi till vår kompletta produkt-
katalog eller vår hemsida www.eurolube.com.
Pumpens förmåga att leverera vätska baseras på lufttryck 
(bar) och luftflöde (l/min) till luftmotor, samt mottryck som 
uppstår mellan pump och utloppsventil.

VARNING!

 

Pumparna får EJ användas för pumpning av 

bensin eller andra kemikalier. Rikta aldrig utloppsmun-
stycke mot någon kroppsdel eller någon annan person. 
Vätska kan lätt tränga in igenom hud och förorsaka skador. 
Läs dessa intruktioner innan pumpen installeras, används 
eller vid service.

ÖVERSKRID EJ MAX ARBETSTRYCK

PART NO / ART.NR

15742

15741

15740

Pump ratio / tryckförhållande

15:1

15:1

15:1

Maximum air pressure / max lufttryck

10 bar (150 psi)

10 bar (150 psi)

10 bar (150 psi)

Minimum air pressure / min lufttryck

4 bar (29 psi)

4 bar (29 psi)

4 bar (29 psi)

Delivery per minute / kapacitet per 
minut

15 l/min @ 10 bar

15 l/min @ 10 bar

15 l/min @ 10 bar

Air inlet / luftanslutning

1/4” BSP (F/Inv.)

1/4” BSP (F/Inv.)

1/4” BSP (F/Inv.)

Fluid outlet / utloppsanslutning

3/4” BSP (F/Inv.)

3/4” BSP (F/Inv.)

3/4” BSP (F/Inv.)

Fluid inlet / inloppsanslutning

3/4” BSP (F/Inv.)

Weight / vikt

4,2 kg

4,9 kg

6,5 kg

TECHNiCAL DATA / TEKNisKA DATA

MEAsUREMENTs / MÅTT

D

B

A

C

MEAsUREMENTs 
/ MÅTT

15742

15741

15740

A

710

500

1180

B

270

270

270

C

32

32

32

D

445

230

910

Summary of Contents for E80 Series

Page 1: ...med låg under hållskostnad Utmärkt till applikationer där man behöver olja i långa rörledningar och med flera samtidiga tappningar För detaljerad information hänvisar vi till vår kompletta produkt katalog eller vår hemsida www eurolube com Pumpens förmåga att leverera vätska baseras på lufttryck bar och luftflöde l min till luftmotor samt mottryck som uppstår mellan pump och utloppsventil VARNING ...

Page 2: ...NT 205128 PART NO 15740 15741 15742 ART NR 15740 15741 15742 E80 series 15 1 OIL PUMP 2 1 2 3 3 3 4 5 12 13 14 15 16 17 18 19 19 10 11 9 8 6 7 20 20 23 22 22 21 21 24 25 28 28 29 30 31 32 33 34 35 36 46 26 27 37 38 40 41 42 43 44 45 39 ...

Page 3: ...h the exception for when testing a pump and great caution should be exercised All screws and threaded components are right handed unless otherwise indicated Avoid damage to packings and all moving surfaces When servicing the pump all parts should be protected from dirt especially the cylinder and the central bar Keep the working area and tools clean Be very careful when dismantling and assembling ...

Page 4: ...replace the filter 3 Loosen the silencer s Pos 16 4 screws Pos 17 and remove the protective cover Pos 15 Unscrew the 6 screws Pos 18 which keep the mechanism Pos 13 in position 4 Do not loose any of the O rings between the air motor and valve mechanism Use some silicon grease to keep them in place 5 It is now possible to inspect the valve mechanism Pos 13 and exchange it or replace it 6 To inspect...

Page 5: ...ean and grease all gasket bearing surfaces including O rings and gaskets with teflon grease when reassembling pump 4 Try to use paraffin to clean pump parts If water based cleaners are used wipe parts clean dry immediately to avoid corrosion Pumpen är avsedd för icke korrosiva och petroleumbaserade vätskor Pumpen får EJ användas för andra ändamål eller för pumpning av bensin eller andra kemikalier...

Page 6: ...n out 1 Check fluid level in drum tank in relation to riser tube outlet point 2 Check spring and valve for correct operation and seating Check for foreign objects jammed in foot valve 3 Check for foreign objects in piston valve seat Check seals for wear and damage Oil is coming out of the leakage hole in the outlet body Packing between air motor and pump is worn out or dam aged See Service exchang...