19
•
EN
Switching on and off
1
Switch on the machine with the power switch (lights up). The display shortly indicates
“
WELCOME
“. Then the machine starts with the warm-up process and the display
indicates “
WARMING UP
“.
2
While the unit is warming up, fog output will not be possible yet. Program the necessary
menu settings with the control panel. Once the warm-up process is completed, fog output
will be possible. The display indicates “
READY TO FOG
“. Additionally, a “
W
“ for wireless
and an “
S
“ for fluid sensor is indicated if these functions are activated.
3
After operation, switch off the machine with the power switch.
The output nozzle will heat up during operation. Therefore do not touch the nozzle
until it has cooled down completely!
Prior to transportation, allow the machine to cool down and completely empty the
fluid tank. Drain the water from the water tanks completely via the two drain valves.
Never operate the fog machine without fog fluid. Fire hazard due to overheating!
Besides, the unit may be damaged.
During operation fog
emission may stop. In this case the device is heating up again.
After a short period, the machine will be ready to emit fog again. This process
guarantees an appropriate vaporization temperature and the best fog emission
possible. The temperature is regulated by a high-quality thermostat.
Display and operating buttons
The device is equipped with 6 operating buttons and an LCD screen displaying all operation statuses of the
machine. All current operating parameters are automatically stored in non-volatile memory, allowing the machine
to be powered down without losing function settings.
Menu Settings
Indication
Value
Function
Interval set
1-200s
Setting time intervals for timer operation
Duration set
0-200s
Setting the output duration for timer operation
Timer Out
1-100%/
NONSTOP BURST*
Setting the fog output volume for timer operation
Volume Out
1-100%/
NONSTOP BURST*
Setting the fog output volume for continuous
operation
DMX512 Add
1-512
Setting theDMX512 address
WIRELESS
ON/OFF
Wireless remote on/off
Fluid Sensor
ON/OFF
Fluid sensor on/off
* NONSTOP BURST = maximum fog volume (only in fogger operation)
Button
Function
FUNCTION
Selects functions
UP/DOWN
Selects options/setting values
TIMER
Timer mode
VOLUME
Continuous mode
MANUAL
Manual mode
FUNCTION
UP
DOWN
TIMER
VOLUME
MANUAL
Summary of Contents for WLF-1500 Water Low Fog PRO