00044394.DOC, Version 1.0
14/18
DESCRIPTION OF THE DEVICE
Features
Compact follow-spot
• Basic equipment: built-in fan, iris, blackout and on/off-switch, splinter protection, two easily adjustable
lenses.
• 5 handles at the right places
• Gobo holder for 66 mm gobos for projection of motives
• High-performance follower with stable housing and high lifetime in mobile operation
INSTALLATION
Installing/Replacing the lamp
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
For the installation, you need one MSR 575/2 GX-9.5 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter regularly and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1:
Unscrew the two fixation-screws of the service lid on the bottom and remove the lamp protection-
cover.
Step 2:
If replacing the lamp, remove the old lamp from the socket.
Step 3:
Insert the lamp into the lamp-socket.
Step 4:
Replace the protection-cover, close the service lid and tighten the screws.
Do not operate this device with opened protection-cover!
Mount the VFL-575 on the stand.