00046978.DOC, Version 1.0
21/22
Channel 6 – Lens 6
Value:
Function:
000 – 010
Off
011 – 045
Red on
046 – 080
Green on
081 – 115
Blue on
116 – 150
Red and green on
151 – 185
Red and blue on
186 – 220
Green and blue on
221 – 255
Red, green and blue on
Channel 7 – Strobe
Value:
Function:
000 – 010
Off
011 - 255
Flash, with increasing speed
Channel 8 – Auto Mode: Internal Programs, Sound Controlled Mode
Value:
Function:
000 – 010
Off
011 – 024
Program 1
025 – 038
Program 2
039 – 052
Program 3
053 – 066
Program 4
067 – 080
Program 5
081 – 094
Program 6
095 – 108
Program 7
109 – 122
Program 8
123 – 136
Program 9
137 – 150
Program 10
151 – 164
Program 11
165 – 178
Program 12
179 – 192
Program 13
193 – 206
Program 14
207 – 220
Program 15
221 – 250
Program 16
251 – 255
Sound Controlled Mode
Channel 9 – Speed in Auto Mode
Value:
Function:
000 – 255
Increasing speed
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).