00064545.DOC, Version 1.0
22/23
3-Channel Mode:
Channel 1 - Auto Programs
Value:
Function:
000 – 009
Blackout
010 – 019
Auto program 1
020 – 029
Auto program 2
030 – 039
Auto program 3
040 – 049
Auto program 4
050 – 059
Auto program 5
060 – 069
Auto program 6
070 – 079
Auto program 7
080 – 089
Auto program 8
090 – 099
Auto program 9
100 – 109
Auto program 10
110 – 119
Auto program 11
120 – 129
Auto program 12
130 – 139
Auto program 13
140 – 149
Auto program 14
150 – 159
Auto program 15
160 – 169
Auto program 16
170 – 179
Auto program 17
180 – 189
Auto program 18 (
random
)
190 – 255
Sound control
Channel 2 - Speed
Value:
Function:
000 - 255
Increasing speed of the program settings
under channel 1 (010 - 189)
Channel 3 – Strobe
Value:
Function:
000 – 009
No function
010 - 255
Flash, with increasing speed
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!