![EuroLite LED Neon Flex User Manual Download Page 16](http://html1.mh-extra.com/html/eurolite/led-neon-flex/led-neon-flex_user-manual_2438369016.webp)
00053314.DOC, Version 1.0
16/18
90° Installation 180° Installation
5 cm channel L-connector 5 cm channel
Other types of installation
End cap
The last tube has to be terminated with an end cap. Please
make sure that you stick the end cap on the tube.
Connection to the mains
Connect the last tube to the Controller Basic for LED Neon Flex 230V EC RGB, making sure that the poles
are correct. The maximum load of the controller is 200 W. Connect the power cord to the mains. Make sure
that the outlet is in a dry area. After connecting the lighting chain to the mains, the LEDs start burning.
Note:
The lighting chain may not be connected to dimming packs! After the installation, the power supply
cord, the plug, and the connector must be free of any tractive forces and rotary forces. The lighting chain
must never be covered with any object.