00135564, Version 1.0
26/28
Dimming Curves options:
Linear
LINEAR:
the increase in light intensity appears to be linear as DMX value is increased.
SQUARE LAW:
light intensity control is finer at low levels and coarser at high levels
INVERSE SQUARE LAW:
light intensity control is coarser at low levels and finer at high levels
S-CURVE:
light intensity control is fine at low levels and high levels and coarser at medium levels.
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled with the
master unit without the need for a DMX controller. The devices must be set to the corresponding operating modes.
1 Configure all slave units before connecting the master unit: Press the
MENU
button so many times until
SLnd
is indicated on the display. Confirm with the
ENTER
button. You can then select
SL1
. Confirm with the
ENTER
button.
2 To determine the master device press the
UP
or
DOWN
button until the menu item
Mast
appears in the
display. Confirm with the
ENTER
button.
3 Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX
output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been connected in
a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller to the DMX input of
the master unit.
4 Set the master unit to the desired operating mode. The interconnected devices will now operate synchronously.
DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 4 control channels. However, it
can also be switched to a mode with 1, 2 or 3 channels if different functions are required. To be able to operate the
device with a DMX controller, the DMX starting address must be set. The starting address depends upon which
DMX controller is being used. Please refer to the controller’s documentation.
1 Press the
MENU
button until
Addr
is indicated in the display. Confirm with the
ENTER
button. Use the buttons
UP
and
DOWN
to select the desired DMX address. Confirm with the
ENTER
button again.
2 Now press the
UP
or
DOWN
buttons until
Chnd
is indicated in the display. The display indicates
1 CH
(1 DMX
channel),
2 CH
(2 DMX channels),
3 CH
(3 DMX channels) or
4 CH
(4 DMX channels). Use the buttons
UP
or
DOWN
to select the desired DMX channel mode. Confirm with the
ENTER
button.
3 A dot will flash on the display when DMX signals are being received.
Note: Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX chain. If several devices are addressed similarly, they will
work synchronously.
Functions in 1-channel mode
Channel
Function
Value
Details
CH1
Master dimmer
000 – 255
Total brightness 0-100%
*
*
= With preset Zoom from the main menu (