00040337.DOC, Version 1.1
9/15
DANGER TO LIFE!
The installation must only be carried out by a qualified electrician!
OPERATION
After you connected the lighting chain to the mains, the LEDs start burning.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
There are no serviceable parts inside the device. If defective, please dispose of the unusable lighting chain
in accordance with the current legal regulations.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Article No.:
50499130 / 50499131
50499140 / 50499141
Power supply (via DC 12 V power-unit):
230 V AC, 50 Hz ~
230 V AC, 50 Hz ~
Power consumption/meter
max. 0.46 W
max. 0.3 W
Protection grade:
IP 44
IP 44
Maximum ambient temperature
T
a
:
45° C
45° C
Maximum housing temperature
T
B
(steady state): 60° C
60° C
Min. distance from flammable surfaces:
0.5 m
0.5 m
Min. distance to lighted object:
0.1 m
0.1 m
Number of 5mm LEDs:
666
333
LED distance:
15 cm
15 cm
Consumption/LED:
0.2 W
0.2 W
LED lifetime:
50000 h
50000 h
Color temperature:
3000 K / 6400 K
3000 K / 6400 K
Length:
100 m
100 m
Weight/meter:
0.04 kg
0.035kg
Please note: Every information is subject to change without prior notice. 05.02.2009 ©