00026529, Version 2.1
16/20
CAUTION, HOT LAMP!
Let the lamp cool down for
10 min. Change the lamp by
loosening left & right screws.
Adjust the lamp position by
turning screws A, B and C.
A
C
B
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 800° C.
For the installation, you need a HX600 GKV 240V/600W G-9.5 lamp.
Procedure:
Step 1:
Unscrew the knurled screws of the lamp housing and carefully remove it.
Step 3:
If replacing the lamp, remove the old lamp from the socket.
Step 4:
Insert the new HX600 GKV 240V/600W G-9.5 lamp into the lamp-socket.
Step 5:
Replace the lamp housing onto the device and tighten the knurled screws.
Lamp base
Retention box
GKV Lamp
Knurled screw
Do not operate this device with opened lamp housing!
Lamp adjustment
The lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve
light performance.
Strike the lamp, open the shutter and the iris, set the
dimmer intensity onto 100 % and focus the light on a flat
surface (wall). Center the hot-spot (the brightest part of
the beam) using the 3 adjustment screws
"A, B, C”
. Turn
one screw at a time to drag the hot-spot diagonally
across the projected image. If you cannot detect a hot-
spot, adjust the lamp until the light is even.
To reduce a hot-spot, pull the lamp in by turning all three
screws
"A, B, C”
clockwise ¼-turn at a time until the light
is evenly distributed.