00041214.DOC, Version 1.0
31/32
DMX-protocol
Channel
Function
Value
Description
0 - 10
CLOSED LASER AND SCANNER STOP
WORKING
11 - 120
DYNAMIC PATTERNS
121 - 250
STATIC PATTERNS
CH1
MODE
251 - 255
SOUND ACTIVE
CH2
PATTERN
SELECTION
0 - 255
NUM N STATIC STATE/ DYNAMIC PATTERNS
CH3
POSITION-X
0 - 255
ADJUST POSITION-X
CH4
POSITION-Y
0 - 255
ADJUST POSITION-Y
CH5
SCAN SPEED
0 - 255
0 IS SPEEDY, 255 IS SLOW
CH6
DYNAMIC
PATTERNS
PLAY SPEED
0 - 255
0 IS SPEEDY, 255 IS SLOW
CH7
STATIC
PATTERNS
PATTERN
SIZE
0 - 255
0 IS SMALL 255 IS BIG
NOTE:
40 dynamic patterns and 40 static patterns, some static patterns can adjust size, all the dynamic
patterns cannot adjust size.
7. CLEANING AND MAINTENANCE
Laser products in discotheques are technical working installations and fall under the Equipment Safety Act.
This is why they must fulfill its requirements.
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Always disconnect from the mains when the device is not in use or before cleaning it.
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use