![EuroLite DMX Merger User Manual Download Page 10](http://html1.mh-extra.com/html/eurolite/dmx-merger/dmx-merger_user-manual_2437821010.webp)
00061057.DOC, Version 1.1
10/12
4.1 Features
DMX merger
• Enables two separate consoles to control one DMX system
• LTP, HTP, merge or backup mode selectable
• LED indicator for power and DMX signals
• 2 inputs & 1 output connector on the front and on the rearpanel
• Connections XLR 3-pin
• Rack mounting
Power switch
Power LED
DMX LEDs
DMX input sockets
DMX output socket
DMX output socket
DMX input sockets
DIP-switches DMX-address
DIP-switches Mode select
Power input socket
4.2 Installation
Install the device on a plane surface or install it in a rack.
Rack-installation: This device is built for 19" racks (483 mm). The rack you use should be a Double-Door-
Rack where you can open the frontpanel and the rear panel. The rack should be provided with a cooling fan.
When mounting the device into the rack, please make sure that there is enough space around the device so
that the heated air can be passed on. Steady overheating will damage your device.
You can fix the device with four screws M6 in the rack.
4.3 DMX-512 connection
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
Caution:
At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.