EuroLite AKKU LED IP FL-5 COB 3200K User Manual Download Page 9

 

00101959.DOC, Version 1.0 

9/12 

Please  make  sure  that  there  are  no  obvious  transport  damages.  Should  you  notice  any  damages  on  the 
power  unit  or  on  the  housing,  do  not  take  the  device  into  operation  and  immediately  consult  your  local 
dealer. 

 

The device falls under protection-class III. The device may only be recharged with the enclosed power unit. 
Always plug in the power unit last. The power plug must always be inserted without force. Make sure that the 
plug is connected properly with the outlet. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it 
on  immediately.  The  arising  condensation  water  might  damage  your  device.  Leave  the  device  switched  off 
until it has reached room temperature. 

 

HEALTH HAZARD!

Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!

 

 

Never operate the device without protective shield! 

 

Replace any cracked protective shield 

 

Keep away children and amateurs! 

OPERATING DETERMINATIONS 

This device is a general purpose luminaire. Thanks to the integrated rechargeable battery it is ideally suited 
for mobile applications. 

 

The device can be operated via the integrated lithium ion rechargeable battery (3.7 V 2200 mAh) which can 
be recharged when connecting the device to the mains.  

 

This product is only allowed to be operated with the voltage given on the type-plate. 

 

This  device  is  splash-proof  (IP X4)  and  therefore  qualified  for  indoor  and  outdoor  use.  In  order  to  maintain 
this  protection  grade  after  opening  the  housing,  any  rubber  sealings  must  be  examined  for  damages  and 
always be correctly installed. 

 

For outdoor use, the installer must always make sure to connect a rubber cable H05RN-F or HO5RR-F. For 
installations in the ground, an underground power cable NYY must be used! 

 

All valid instructions concerning the installation of cables outdoors or in the ground must be adhered! 

 

The  ambient  temperature  must  always  be  between  -5°  C  and  +45°  C.  Keep  away  from  direct  insulation 
(particularly in cars) and heaters. 

 

The maximum relative humidity is 100 % with an ambient temperature of 25° C. 

 

This device must only be operated in an altitude between -20 and 2000 m over NN. 

 

This luminaire must never be covered. Danger of burning! 

 

The  symbol 

- - -m

  determines  the  minimum  distance  from  lighted  objects.  The  minimum  distance 

between light-output and the illuminated surface must be more than the given value. 

 

The maximum ambient temperature 

T

a

 = 45° C must never be exceeded. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth. 

 

Please use the original packaging if the device is to be transported. Make sure that  you pack the device in 
the original state. 

 

Please consider that unauthorized modifications on the device are forbidden due to safety reasons!

 

 

If this device will be operated in any way different to the one described in this manual, the product may suffer 
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc. 

 
 
 
 
 
 
 

Summary of Contents for AKKU LED IP FL-5 COB 3200K

Page 1: ......

Page 2: ...EN 7 INTRODUCTION 8 Features 8 SAFETY INSTRUCTIONS 8 OPERATING DETERMINATIONS 9 INSTALLATION 10 Mobile use 10 OPERATION 10 CLEANING AND MAINTENANCE 11 TECHNICAL SPECIFICATIONS 11 Diese Bedienungsanlei...

Page 3: ...Sie sich f r einen EUROLITE AKKU LED IP FL 5 COB 3200K entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den A...

Page 4: ...t werden k nnen gilt besonders f r Epileptiker Das Ger t darf niemals ohne Schutzscheibe betrieben werden Ersetze jede gebrochene Schutzscheibe Kinder und Laien vom Ger t fern halten BESTIMMUNGSGEM E...

Page 5: ...bsmodus und der Umgebungstemperatur ab Bei K lte reduziert sich die Laufzeit deutlich Laden Sie den Akku vor dem ersten Einsatz vollst ndig auf Akkumulatoren und Batterien d rfen nicht im Hausm ll ent...

Page 6: ...as Ger t vom Netz Anderenfalls wird auch bei ausgeschaltetem Ger t stets ein geringer Strom verbraucht 4 Das Ger t erw rmt sich w hrend des Ladevorgangs dies ist ein normaler Vorgang 5 Laden Sie einen...

Page 7: ...eit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 100 240 V AC 50 60 Hz ber 5 V DC 0 5 A Ladenetzteil oder ber KfZ Bordspannungsstecker beides im Lieferumfang enthalten Gesamtanschlusswert...

Page 8: ...nd powerful Floodlight with one white 5W COB LED Ideal LED luminary for outdoor use Protection grade IP 44 Indoors or outdoors usable everywhere Including portable stand with comfortable handle The in...

Page 9: ...d outdoor use In order to maintain this protection grade after opening the housing any rubber sealings must be examined for damages and always be correctly installed For outdoor use the installer must...

Page 10: ...aration of the item being shipped consulting an expert for hazardous material is required Dispatch battery only when the housing is undamaged Tape or mask off open contacts and pack up the battery in...

Page 11: ...ee and moistened cloth Never use alcohol or solvents There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by authorized dealers Should you nee...

Page 12: ...Eurolite is a brand of Steinigke Showtechnic GmbH Andreas Bauer Str 5 97297 Waldb ttelbrunn Germany D00101959 doc Version 1 0 Publ 31 08 2016...

Reviews: