Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly
fastened.
The maximum ambient temperature
T
a
= 45° C must never be exceeded.
Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Attachment
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
The device can be installed in lowered ceilings or empty walls.
The installation element or ceiling element must not be thicker than 20 mm.
Please note:
The installation-spot must always be well-ventilated.
Procedure:
Step 1:
Unscrew the fixation screws of the luminary lid on top of the housing and remove it with the glass
plate underneath.
Step 2:
On the baseplate, there are the holes for the installation.
Step 3:
Hold the baseplate onto the location where the device is to be installed.
Step 4:
Mark the boreholes and a hole for the power cord with a pen or a suitable tool.
Step 5:
Drill the holes.
Step 6:
Hold the baseplate in the desired position, slip the power cord through the appropriate hole and
tighten the screws to fix the luminary.
Step 7:
Replace the glass plate and luminary lid and tighten the screws.