00085268.DOC, Version 1.1
19/28
OVERVIEW
HST-150
4026397527322
No. 51930455, EAN
T1.5A/250V
230V 50 Hz
0W
~ 5
Steinigke Showtechnic GmbH Andreas-Bauer-Str. 5
97297 Waldbuttelbrunn Germany www.steinigke.de
XLR occupation:
1: Ground
2: Signal (-)
3: Signal (+)
ON
OFF
Fuse:
T 1.5 A, 250 V
Power supply:
230 V AC, 50 Hz ~
High voltage! Do not open!
Professional installation and maintenance.
Operating temperature: 5°C ~ 45°C
HST-150
1
2
3
4
5
6
INSTALLATION
This device is designed for installation on a trussing system. Please note the following pictures.
Overhead rigging on a trussing system
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national norms during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
1. DMX In plug
2. DMX Out socket
3. Power supply
4. Fuse holder
5. Power On/Off
6. Control board with
operating buttons