00139836.DOC, Version 1.0
14/16
5. INSTALLATION
DANGER TO LIFE!
Please consider the DIN 15560 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The installation should be attached outside areas where persons may walk by or be seated.
5.1 Rack installation
This power distributor is built for 19“ racks / steel cabinet (483 mm). The rack you use should be a double-
door-rack where you can open the front panel and the rear panel. The rack should be provided with a cooling
fan. When mounting the power distributor into the rack, please make sure that there is enough space around
the device so that the heated air can be passed on. Steady overheating will damage your device.
You can fix the power distributor with four M6 screws in the rack.
Be careful when mounting the power distributor into the rack. Put the heaviest devices into the lower part of
the rack.
5.2 Connections
5.2.1 Connection with the mains
Connect the device to the mains with the CEE plug.
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
5.2.2 Outputs
Connect your loads via the output sockets. Please note that the maximum current must never be exceeded.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!