Euroheat WIKING MIRO Range Installation Instructions Manual Download Page 4

©

 

EUROHEAT

 

DISTRIBUTORS (H.B.S) LTD. Jan 2012

E&OE  Instructions Part number IN1273 Ed  A

4

Euroheat Distributors (H.B.S). Ltd.
Unit 2, 
Court Farm Business Park,
Bishops Frome, 
Worcestershire.  WR6 5AY.

www.euroheat.co.uk

[email protected] 

Useful organisations

Solid Fuel Association  

 

 

 

0845 601 4406  

www.solidfuel.co.uk

The National Association of Chimney Sweeps 

01785 811732 

www.chimneyworks.co.uk

HETAS 

 

Ltd. 

     0845 

634 

5626 www.hetas.co.uk

The Model Range Explained 

Thank you for purchasing your stove and helping to protect our environment. Wiking and Euroheat insist on 
progressive development to produce products which are market leading. Our aims are to produce stoves 
with the latest innovations, user friendly operation and high efficiency for lower cost operation.  

This manual offers user information for the range of WIKING MIRO stoves.

Model Identification

You will see on the front page of this document a label which confirms which model you have. This label 
also advises you of the stoves unique serial number. This information is also attached to your stove for 
reference. 

Important

Please ensure the warranty registration form is returned to Euroheat. In this way the model and its history 
will be recorded for reference in the future.

Whilst we are always happy to assist you, please make sure you have read this manual before 
contacting the technical support team. 
Technical Support Telephone Number 01885 491117. E-mail [email protected]

Before Operating this Appliance

The paint used on the stove is a heat resistant paint capable of withstanding  650°C, but it needs to be 
heated for several hours to allow it to cure and attain its full hardness. The lighting procedure should be 
followed and the stove’s first fire limited to a small fire for one hour, after which its size can be gradually 
increased to allow the stove to reach its operating temperature.  As the temperature of the paint increases 
a blue hazy smoke will be apparent as the solvents in the paint are driven out. These fumes may activate 
a smoke detector, if fitted, and during this period the room must be ventilated by leaving the windows 
open and it should not be occupied by people or pets. The time taken for the paint to be fully cured will be 
dependant upon the temperature but you should allow at least six hours. If you re-paint or fit new parts to 
your stove, another period of curing will be necessary but the curing time will be very much shorter.

Hwam
Nydamsvej 53 Dk -8362 Horning Denmark

www.hwam.com

Summary of Contents for WIKING MIRO Range

Page 1: ...f Stoves The above are suitable for use in smoke control areas Wood Models This manual must always be available to the stove operator Serial Number Part No Model Name This manual must be used in conju...

Page 2: ...ructions Subject Page Important Notes 3 Model Identification 4 Curing Process 4 About Different Fuels 5 7 The Clean Air Act and Smoke Control Areas 8 Technical Details 8 Hearths 9 Fireplace Design 10...

Page 3: ...imperative that all air passageways into out of and within the appliance are kept clean All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times...

Page 4: ...Euroheat In this way the model and its history will be recorded for reference in the future Whilst we are always happy to assist you please make sure you have read this manual before contacting the t...

Page 5: ...his will ensure that when the new logs begin releasing gases it will ignite Unburned gases will cause smoke and tar deposits and wastes potential heat Putting on too much wood at one time will both re...

Page 6: ...o allow air to circulate within the stack and storing it under cover for between 18 months and 30 months depending on prevailing climatic conditions The use of a wood moisture content meter will confi...

Page 7: ...f they are split halving the tubes and allowing the moisture to evaporate more easily Similarly it also allows the volatile gases given off when the wood is heated in a stove to be emitted along its f...

Page 8: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Page 9: ...s the floor can accommodate the weight of the appliance and its unsupported flue components If it is installed on a wooden floor or similar the floor must be covered with a non combustible material a...

Page 10: ...ars Golden Mean 1 The stove must always stand perfectly level The provision of a suitable level hearth within the recess is an important consideration when planning a fireplace 2 Sufficient space shou...

Page 11: ...ible back wall 50mm 1 From combustible back wall 100mm 2 From non combustible side wall 100mm 2 From combustible side wall 520mm 3 hearth in front 300mm 1 Distance to 450 sidewall 380mm 4 Distance fro...

Page 12: ...tions and makes it possible to over fire the stove which can seriously damage it In this instance a flue draught stabiliser may need to be fitted or if it is wind assisted excessive flue draught a sta...

Page 13: ...tos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the po...

Page 14: ...ser never to operate the stove with the furnace door open and that the user is aware of the requirement of a suitable fire guard where children the old or infirm may come into contact with the applian...

Page 15: ...E OE Instructions Part number IN1273 Ed A 15 EUROHEAT DISTRIBUTORS H B S LTD Jan 2012...

Page 16: ...Bishops Frome Worcestershire WR6 5AY Reception 01885 491100 Email info euroheat co uk...

Reviews: