IN13 Aperture Size

370mm Min

406mm Min/470mm Max

550mm Min/

580mm Max

Technical Data, Intermittent Operation

Model

Heat

Output 

Wood

Refuelling

Interval 

Wood

Energy 

Efficiency

Wood

Heat 

Output 

Smokeless 

Coal**

Refuelling

Interval 

Smokeless 

Coal**

Energy 

Efficiency

Smokeless 

Coal**

IN13 Wood

5 kW

0.70 hr

77.1% Net
70.2% Gross

IN13 Multifuel

5 kW

0.70 hr

77.1% Net
70.2% Gross

3.5 kW

1.05 hr

82.8% Net

75.4% Gross

Technical Data, Continuous Operation

Model

Heat 

Output 

Wood

Refuelling

Interval 

Wood

Energy 

Efficiency

Wood

Heat Output 

Smokeless

Coal**

Refuelling

Interval 

Smokeless 

Coal

Energy 

Efficiency

Smokeless 

Coal 

IN13 Wood

5.4 kW

1.45 hr

83.4% Net 
75.9% Gross

IN13 Multifuel

5.4 kW

1.45 hr

83.4% Net 
75.9% Gross

3.5 kW

4 hr

78.3% Net

71.2% Gross

General Technical Data

Model 

Model 

Number

Weight KG

Flue 

Draught 

Nominal

Flue Gas 

Mass Flow 

g/s

Flue Gas 

Temperature 

Down Stream of 

Flue Spigot 

Free Air 

Requirement

IN13 Wood

IN13*

108

12pa

4.9

350 

0

c

0mm²**

IN13 Coal

IN13*

108

12pa

3.8

210

0mm²**

** In well sealed properties additional free 
air might be required.

Summary of Contents for Nestor Martin IN13

Page 1: ...r Martin IN13 IN1208 Edition B June 2010 Euroheat Natural Energy Company This Manual Must Always be Available to the Stove Operator This manual must be used in conjunction with document IN1173 The Woo...

Page 2: ...ed with a suitable fire resistant sealant we recommend Fraxfill available from Euroheat Part No MS9045 Some so called Heat Proof mastiks will only stand a temperature of 300 C before they start breaki...

Page 3: ...istory will be recorded for reference in the future For the latest versions of manuals technical information accessories and spare parts visit the Euroheat web site Stoves Supplied Through Euroheat Au...

Page 4: ...ative that all air passageways into out of and within the appliance are kept clean All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times Consid...

Page 5: ...1 05 hr 82 8 Net 75 4 Gross Technical Data Continuous Operation Model Heat Output Wood Refuelling Interval Wood Energy Efficiency Wood Heat Output Smokeless Coal Refuelling Interval Smokeless Coal En...

Page 6: ...rt number IN1208 Edition B 6 Supplied with the Stove Flue Spigot and Self adhesive Rope Stove Operating and Ash Pan Tool Approx 1 4m Self adhesive Rope Which may be used to form a seal between the sto...

Page 7: ...d fire back should be removed The hearth and surrounding masonry work should be inspected for soundness and any remedial work undertaken if required The hearth should be level to give a stable base fo...

Page 8: ...reach over three hundred degrees Celsius all materials used for constructing the housing must be both non combustible stable at high temperatures and insulate any part of the building which may be aff...

Page 9: ...d single wall liners Weatherproof chimney pot and parged at a steep angle to disperse rain water Sound chimney brick work Stainless steel liner Flexible to single wall adapter if flexible liner is fit...

Page 10: ...gain access to fit the flue spigot This baffle is held in place by two bolts and the baffle MUST be replaced once the flue has been connected There is a small lenth of self adhesive rope supplied with...

Page 11: ...l never become excessively hot it will become very warm if the stove is kept burning at a high rate For this reason anything attached to the wall will also become very warm This may cause damage to oi...

Page 12: ...gasses from the fuel If the air supply is abruptly and completely removed the fire will extinguish but the release of gasses will continue for some time These gasses will be above their ignition temp...

Page 13: ...through the door To refit the replacement reverse the procedure Removal of the Upper Protection Plate The upper protection plate is held in place by the two side protection plates To remove 1 lift up...

Page 14: ...that the lug on the bottom of the grate locates in the riddle arm Removal of the Grate Frame With the baffle plate log guard and side protection plates removed Lift out the two cast iron bottom prote...

Page 15: ...pliances without prior notice We make every effort to ensure that the information provided in this document is correct and accurate at the time of printing Continued updates occur to adapt documents t...

Page 16: ...491112 Technical 01885 491117 Reception 01885 491100 Need more info with over 10 000 pages of technical information spare parts product shots news and 1001 other things you will not find a more compr...