To correctly commission the fully installed stove a flue draught measurement gauge will be required. This should
be sufficiently accurate to measure the negative pressure produced in the chimney system. If a flue stabilizer is
fitted it should then be set in accordance with the graphic below, with the stove at maximum setting.
Commissioning
1. Adjusting thermostat setting
1mm
Thermostat
adjustment
screw
The cold setting of the thermostat must be checked before the
stove is operated for the first time.
With the stove cold the gap between the inside left of the
thermostat disc and the cast iron body of the stove should be
1mm. at normal room temperature.
Note the thermostat disc is designed to close at a predetermined
angle.
firing rate
0.04
0.02
0.06
millimetres
inches
firing rate
2. Flue draught measurement
Flue draught measured
with the air wash vent
fully open and all other
air supplies to the fire
closed.
Euroheat can supply flue
measurement gauges
order number MS026.
Note this is not a water
gauge used to measure
gas pressure.