8.

 

INSTALLATION 

(SPECIALIST TECHNICIAN)

INCORRECT INSTALLATION OF THE PRODUCT CAN CAUSE INJURY TO PEOPLE OR DAMAGE 

PROPERTY.  

THE MANUFACTURER CANNOT BE HELD LIABLE FOR THIS. 

 

Any variation or modification of the installation conditions must be authorised in 

advance by EPTA. The operations described in this chapter must be carried out by 

qualified staff. 

To guarantee that people assigned to installing the product work in the appropriate safety situations, we 

suggest  that you carefully follow the installation  procedure described  here.  In every  case, it  is 

recommended to use suitable equipment or clothing: 

safety shoes, safety gloves, spirit level. 

 

We also suggest you use all the tools or protective clothing required by legislation, or by the laws in force 

in the country of installation. 

8.1 

OPENING THE PACKAGE 

The cabinet is provided in one of the following ways: 

Platform or pallet (fig. 1)

Crate (fig. 2)

The protective wooden packaging (crate) is opened using suitable tools: it is recommended to cover 

exposed parts and in particular hands, with safety gloves because wood splinters may become detached 

from the packaging. It is recommended to remove the nails, starting from the top part, until the 

appliance is uncovered but still attached to the pallet (packaging platform). 

Therefore: 

Remove protective cover with which the appliance is wrapped.

Visually check that the appliance has not been damaged during transport.

CAUTION: inside the appliance there are components that must be assembled. 

Be very careful not to break or lose them during unpacking operations.  

Slowly remove the protective film from the various components, without tearing it to avoid adhesive 

sticking. If this should happen, remove the residues of glue using appropriate solvents. 

During handling operations, it is forbidden to drag or push the display unit using the 

glass.

 

Fig. 1 

Fig. 2 

Summary of Contents for COMFORT MAXI

Page 1: ...COMFORT Refrigerated display unit USER AND MAINTENANCE MANUAL...

Page 2: ...OF WATER ON THE CABINET DO NOT TOUCH THE APPLIANCE WITH WET OR DAMP HANDS AND FEET DO NOT USE THE APPLIANCE BAREFOOT THE APPLIANCE IS NOT INTENDED FOR USE BY PEOPLE INCLUDING CHILDREN WITH REDUCED PHY...

Page 3: ...3 SEZIONI SECTION DIMENSIONS ABMESSUNGEN DIMENSIONES COMFORT MAXI...

Page 4: ...4 COMFORT MIDI...

Page 5: ...ed to in carrying out the work and putting them in the condition of being able to adopt the necessary measures required to minimise the damage to self or to others authorised to carry out extraordinar...

Page 6: ...er defrosting current if electrical defrosting 5 Power of auxiliary heating systems 6 Power of lamps 7 Number and weight of refrigerant 8 Climate class temperature and relative humidity of the referen...

Page 7: ...deterioration the replacement documentation must be requested directly from Epta 4 2VALIDITY OF THE MANUAL The user is reminded that this manual reflects the state of the art and of the technology us...

Page 8: ...oods beverages with a storage temperature above 0 C 4 C The cabinet is NOT suitable for lowering the temperature of the product but only for storing it The goods placed inside the cabinet MUST already...

Page 9: ...e centre of gravity of the package balanced Fig 1 A Do not overturn the appliance Before inserting the forks of the lift truck check that these cover the entire depth of the package Fig 1 B Otherwise...

Page 10: ...entrated lighting units or to heat sources such as radiators heaters ovens Ensure that there is sufficient air circulation on all sides of the display unit It is totally forbidden to position objects...

Page 11: ...is provided in one of the following ways Platform or pallet fig 1 Crate fig 2 The protective wooden packaging crate is opened using suitable tools it is recommended to cover exposed parts and in part...

Page 12: ...tems must be carried out in accordance with the rules governing their construction installation use and maintenance EUROCRYOR declines any responsibility vis vis the user and vis vis third parties for...

Page 13: ...The controller display lights up o The compressor turns on o The interior fans operate check to see that air circulates o Switch on the lights using Fig 1 panel with condensing unit 9 2 1 COUNTER WITH...

Page 14: ...d throughout their stay pay the utmost attention Not to exceed the maximum load lines Not to obstruct the air outlet and air intake slots Not to obstruct the flow of refrigerated air To respect the lo...

Page 15: ...or them to have cooled down Cleaning stainless steel parts Some situations are listed below not necessarily of an extraordinary nature which may lead to oxidation phenomena 1 Iron residues left to set...

Page 16: ...o clean and sanitise floors tiles and washable surfaces as they can have an oxidising corrosive effect on stainless steel 11 1 2 CLEANING THE CONDENSING UNIT OPERATOR It is recommended to clean the co...

Page 17: ...he goods into other refrigerators Wait for the counter to reach the ambient temperature Remove the shelves Caution in counters with CONDENSING UNIT the condensation water evaporates only when the coun...

Page 18: ...work must be carried out in the absence of voltage Act on the main wall switch to switch off the power supply Caution all power circuits must be disconnected before accessing the terminals 12 1 REPLA...

Page 19: ...product the appliance is equivalent when the weight of the appliance returned is not greater than double the weight of the appliance delivered The rates for any additional components to dispose of or...

Page 20: ...ot covered by warranty 6 3 The company will remedy by way of refund of the total or partial price where relevant as a discount on an outstanding portion of the price or at its discretion by way of rep...

Page 21: ...ies representations statements liabilities and other terms of any nature implicit in the law and statutes and or elsewhere which will all be excluded in the measure admitted by the law and the company...

Page 22: ...44 Via dell Industria 257 35047 Solesino PD ITALY Tel 0429 707311 Fax 0429 706000 http www eurocryor com e mail sales eurocryor it...

Reviews: