TO MAKE A DCF RECEPTION ATTEMPT
-
To perform a manual search for the DCF signal (e.g., if you have mounted the
radio wall clock in a different location), press and hold the UP button until the
radio tower symbol in the display goes out.
Thus, you can switch the DCF reception off.
-
Afterwards, press and hold the UP button again until the radio tower symbol
starts to fl ash. A new search for the DCF signal will now be initiated.
MANUAL SETTINGS
After completion of the DCF reception attempt, you can make some additional
settings to adjust the display to your location and your individual needs.
Furthermore, it is possible to set the time manually, in case the DCF signal could
not be received.
-
Keep the button MODE pressed to activate the setting function.
-
The language selection for the display of the weekdays fl ashes next to the time
display.
-
Set the desired language using the UP or DOWN button:
EN=English/DE=German/FR=French/IT=Italian/SP=Spanish/DU=Dutch/
SW=Swedish
-
Press the MODE button again and use the UP or DOWN key as described above
to consecutively set the year, month, date and the display sequence for date/
month, the display format (12h/24h), the hours and minutes.
-
Press the MODE button again to save the settings.
Keep the corresponding setting buttons pressed in order to continuously
change the value to be set.
TEMPERATURE INDICATION
The lower display row indicates the temperature values for the indoor and outdoor
temperatures.
-
Press the MEM button to display the mininum values.
-
Press the MEM button again to display the maximum values.
-
Press and hold the MEM button to delete the minimum and maximum values.
-
Press the °C/°F button to toggle the unit for the temperature display.
If the measured temperature values are outside the metering range , the
display shows HHH (temperature too high) or LLL (temperature too low).
If the display of the outdoor temperature shows dashes, there is an inter-
ruption of the radio contact between outdoor sensor and clock. In this case,
check the batteries of the outdoor sensor and check if the range of the sys-
tem has been exceeded. Electric devices and metallic barriers may interfere
with the transmission range too.
Press and hold the DOWN button to start a manual reception attempt for the
outdoor sensor.
DISPLAY
Press the MODE button briefl y to change the display type for the time and calendar.
Each keystroke on the MODE key switches to the next display type:
Time with second indication > Time with weekday indication > Time of the 2nd time
zone with weekday indication > Time of the 2nd time zone with second indication.
SETTING THE 2ND TIME ZONE
The clock can display two time zones. Set this time as follows:
-
Press and hold the MODE button while the time of the 2nd time zone is displayed
(ZONE will appear on the display).
-
Set the time difference to the normal time display using the UP or DOWN button.
The setting range is -13 to +15 hours.
-
Press the MODE button again to save the settings.
CLEANING AND MAINTENANCE
Apart from replacing the batteries, the product does not require any maintenance
and should never be disassembled.
Please use a soft, dry, clean cloth for cleaning.
Do not use aggressive detergents as these can cause discoloration of the case.
DISPOSAL
a) Product
Electronic devices are recyclable waste materials and must not be disposed
of in the household waste!
Please dispose of the product, when it is no longer of use, according to the
current statutory requirements.
Remove any inserted battery and dispose of it separately from the product.
b) Batteries and Rechargeable Batteries
The end user is legally obliged (Battery Regulation) to return used batteries and
rechargeable batteries. Do not dispose of used batteries in the household waste!
Contaminated batteries/rechargeable batteries are labelled with these sym-
bols to indicate that disposal in the household waste is forbidden. The sym-
bols for the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead
(marking can be seen on the battery/rechargeable battery, e.g., underneath
the refuse bin symbol shown on the left).
You can dispose of your used batteries/rechargeable batteries free of charge at your
community’s collection point or any place where batteries/rechargeable batteries
are sold!
You thereby fulfi l your statutory obligations and contribute to the protection of the
environment.
DECLARATION OF CONFORMITY (DOC)
The manufacturer hereby declares that this product conforms to the fundamental
requirements and the other relevant regulations of Directive 1999/5/EC.
You can fi
nd the Declaration of Conformity for this product at
www.conrad.com.
TECHNICAL DATA
Operating voltage:
3 V/DC (wall clock and outdoor sensor)
Battery:
2 x 1.5 V AA/Mignon (wall clock)
2 x 1.5 V AAA/Mignon (outdoor sensor)
Battery life:
approx. 2 years
Transmission frequency:
433 MHz
Range:
up to 30 m (direct visual contact)
Measuring range indoor temperature:
-10 to +60 °C / +14 to +140 °F
Measuring range outdoor temperature:
-30 to +60 °C / -22 to +140 °F
Thermometer resolution:
0.1 °C / 0.2 °F
Measuring interval of outdoor sensor:
43 - 47 s
Dimensions:
254 x 254 x 40 mm (wall clock)
105 x 38 x 18.5 mm (outdoor sensor)
Weight:
163 g (wall clock)
36 g (outdoor sensor)