12
96
hEATiNg, hOT wATEr & Air CON
109-0006-08EN - 21/09
12.1.3
CP E classic energy selector switch (optional accessory)
For vehicles with Truma Combi D and the CP classic control element, the CP E classic energy selector switch is additionally
installed in the area of the sliding door.
Selecting electric operation (230 volts)
1.
Turn the rotary knob (Fig. 59, item 2) to position 3
(1800 W) or 4 (900 W). The yellow LED (Fig. 59, item 1)
signals electric operation with 230 volts.
Selecting diesel operation
1.
Turn the rotary knob (Fig. 59, item 2) to position 5.
Selecting mixed operation
1.
Turn the rotary knob (Fig. 59, item 2) to position 6 or 7.
10900360
230 V
Combi E
2
1
5
4
3
7
6
1
Yellow LED is lit when in electric operation
2
Rotary knob for energy selection
3
Electric operation, 230 volts, 1800 W
4
Electric operation, 230 volts, 900 W
5
Diesel operation
6
Mixed operation
(diesel and 900 W electric operation)
7
Mixed operation
(diesel and 1800 W electric operation)
Fig. 59
CP E Classic energy selector switch
NOTE!
Mixed operation is not possible in summer operation mode. At this setting, the heater automatically
selects electric operation with the preset electrical power of 900 W or 1800 W.
In winter operation mode, electrical mode has priority. If the electrical heating is insufficient, diesel
operation is added.