12
94
hEATiNg, hOT wATEr & Air CON
109-0006-08EN - 21/09
12.1.2
Setting the operating mode using the CP classic control element
The CP classic control element is installed in the area of the sliding door.
1
2
8
9
3
4
7
5
6
1
Rotary knob room temperature, continuously adjustable, step 1-5 (illuminated by green "Operating" LED)
2
Rotary switch
3
Green "Operating" LED
4
Summer operation (water temperature 40 °C or 60 °C)
5
Winter operation (heating without controlled water temperature)
6
Winter operation (heating with controlled water temperature)
7
Rotary “Off” switch
8
Yellow LED lights up “Boiler heating phase” (goes out when the set water temperate is reached)
Yellow LED flashes “warning”
9
Red LED is lit or flashing “Error”
Fig. 58
Control element CP classic
The CP classic control element allows setting the following operating modes:
Summer operation: only hot water without heating
Winter operation: heating operation with controlled water temperature
Winter operation: heating operation without controlled water temperature
Winter operation: heating operation with drained water system
If one of these operating modes is activated, the green LED behind the rotary knob (Fig. 58, item 1) will light up.
NOTE!
If one of the following situations occur, please follow the instructions in the separate operating manual
supplied by the manufacturer.
)
The green LED does not light up despite the operating mode being set.
)
The yellow LED is flashing.
)
The red LED is lit or flashing.