Euro-Pro EP621H Owner'S Manual Download Page 3

OPERATING INSTRUCTIONS

GETTING TO KNOW  YOUR LIGHTWEIGHT 

UPRIGHT  VACUUM

Fig. 19

Changing the Belt

• Remove the brush carefully by first 

lifting the right side of the brush and 

then the left side of the brush.  Be 

careful not to lose the end caps and 

washers (x2).  (Fig. 18)

• If the belt has broken, remove any 

loose pieces of broken belt before 

replacing with new belt. 

• To install a new belt, slip one end of 

the belt over the gears on the motor 

shaft and then slip the other end 

over the pulley end of the brush. 

• After checking that the end caps 

and washers are on correctly, 

re-install the brush assembly.

• Turn the brush assembly by hand to 

make sure that the belt is not 

twisted and all rotating parts turn 

freely.

• Replace the brush cover and 

screws. (Fig. 21)

IMPORTANT

:

This unit is equipped 

with a motor protective thermostat.  If 

for some reason the vacuum cleaner 

should overheat, the thermostat will 

automatically turn the unit off.  Should 

this occur:

• Push the On/Off button once.

• Disconnect the plug from the 

power source.

• Check the source of overheating 

problem. (i.e. clogged hose or 

filter)

• If clogged hose or filter is found, 

unclog the hose and replace the 

filters.

• Wait at least 45 minutes before 

attempting to reuse the vacuum.

• After unit has cooled down for 

45 minutes, plug in the cleaner 

and push the On/Off button. The 

vacuum should start again.

• If the vacuum still does not start, 

contact customer service at 

1 (800) 798-7398.

Motor Thermostat

W

as

he

rs

Fig. 20

E

nd

 c

ap

s

9

WARNING:

Always disconnect 

from power source when 

servicing or cleaning the unit. Failure to 

do so could result in electrical shock or 

personal injury from cleaner suddenly 

starting.
Occasionally the motorized brush drive 

belt will require changing, the frequency 

will depend upon the amount of use your 

vacuum sees.

• Turn unit “Off” and unplug from 

wall outlet. 

• Remove the motorized floor brush 

from the main unit. (see page 4)

• Use a Phillips #1 screwdriver and 

remove the two (2) front screws 

from the bottom of the motorized 

floor brush. (Fig. 18)

Screws

Fig. 18

Fig. 19

• Remove the brush cover. (Fig. 19)

Technical Specifications

Voltage:

120V.,  60Hz.

Power:

12 Amps

1.

Hand Grip

2.

Hose/Power Cord Holder

3.

Flexible Hose

4.

Removable Hose Handle

5.

Exhaust Filter Cover

6.

Main Unit

7.

Dust Cup Container

8.

Dust Cup Release Lever

9.

Extension Tube

10. On/Off Switch
11. Lifting Handle 
12. Crevice Tool
13. Dusting Brush
14. Motorized Floor Brush
15. Quick Release Cord Holder
16. Lower Cord Holder
17. Lower Hose Holder
18. Inlet Hose
19. Power Cord
20. Brush Roll Warning Light
21. Manual Variable Suction 

Control

22. Trap Door Release Button
23. Intelli-Sense

TM

Filter Monitor

24. Hose Clip

2

Reviews: