OPERATING INSTRUCTIONS cont.

GETTING TO KNOW  YOUR  BIG SHARK

The post motor filter is a washable filter 

but should be replaced every three (3)  

months depending on usage.

• Disconnect from electrical outlet 

before cleaning or changing the filter.

• Remove the exhaust cover from the 

rear of the unit. 

• Rinse the post motor filter in 

lukewarm water and dry the  filter 

completely. Do not use a washing 

machine to rinse the filter. Do not 

use a hair dryer to dry it. Air dry only 

for 24 hours. Never operate the 

vacuum without the post motor filter 

in place.

• A severely clogged filter should be 

thoroughly washed with fresh tepid 

water. A mild detergent can be used 

if required.

IMPORTANT

:

This unit is equipped 

with a motor protective thermostat.  If 

for some reason the vacuum cleaner 

should overheat, the thermostat will 

automatically turn the unit off.  Should 

this occur:

• Push the On/Off button once.

• Disconnect the plug from the 

power source.

• Check the source of overheating 

problem. (i.e. clogged hose or 

filter)

• If clogged hose or filter is found, 

unclog the hose and replace the 

filters.

• Wait at least 45 minutes before 

attempting to reuse the vacuum.

• After unit has cooled down for 

45 minutes, plug in the cleaner 

and push the On/Off button. The 

vacuum should start again.

• If the vacuum still does not start, 

contact EURO-PRO at 

1-800-798-7398.

Motor Thermostat

HEPA Filter

Debris Screen

8.

Dust Cup (Container)

9.

Flexible Hose

10. Oval Brush

11. Crevice Tool

12. Shoulder Strap

13. HEPA Dust Cup Filter 

w/Debris Screen

1. Dust Cup Release Button

2. On/Off Power Switch

3. Intelli-Sense

TM

Filter Monitor

4. Handle

5. Shoulder Strap Attachment Points

6. Suction Hole

7. Exhaust Cover

TROUBLE SHOOTING GUIDE

PROBLEM 

POSSIBLE REASON 

POSSIBLE SOLUTION 

HAND VACUUM 

WILL NOT 

OPERATE 

1.  Power cord not firmly plugged 

into outlet. 

2.  No power in wall outlet. 

3. Needs 

servicing. 

4. Thermostat 

has 

tripped. 

1.  Plug unit in firmly. 

2.  Check fuse or breaker.   

Replace fuse/reset breaker. 

3. Call 

1-800-798-7398. 

4.  Turn the unit off and unplug  

        from outlet. Allow unit to cool 

down; then restart. 

HAND VACUUM 

WILL NOT PICK-UP 

OR SUCTION 

POWER IS WEAK 

1. 

Dust cup is full. 

2. Unit 

clogged. 

3.  HEPA Dust Cup Filter needs 

cleaning or replacing. 

1.  Empty and clean dust cup – 

(see page 4). 

2.  Turn unit off and unplug 

from wall outlet. Remove 

HEPA Dust Cup Filter and 

check for object(s) in air 

duct and remove. 

3.  Clean or replace HEPA  

Dust Cup Filter.  

        (see page 4) 

DUST ESCAPING 

FROM HAND 

VACUUM 

1. 

Dust cup is full. 

2.  HEPA Dust Cup Filter is not 

installed correctly. 

3.  There is a puncture/hole in 

HEPA Dust Cup Filter. 

1.  Empty and clean dust cup. 

(see page 4) 

2.  Review HEPA Dust Cup 

Filter instructions.  

        (see page 4)  

3.  Replace HEPA dust cup 

filter. (see page 4) 

HAND VACUUM 

HOSE OR 

BRUSHES WILL 

NOT PICK-UP 

1. Hose 

clogged. 

2. 

Dust cup is full. 

1.  Remove hose and/or 

bushes. Remove obstruction 

from hose. 

2.  Empty and clean dust cup. 

5

Technical Specifications

Voltage:

120V.,  60Hz.

Power:

7.5 Amps, 900 Watts

2

Reviews: