 2 

LED INDICATORS 

3. 

(R

ed

, Y

ellow

 

and

 G

Reen

 

liGhts

)

To check the internal battery’s charge status, press the Battery Status But

-

3.1 

ton on the front of the Power Pak.
The 

3.2 

led

 lights will indicate the charge level as follows:

A red LED indicates a 50% or less charge and you should immediately 

a. 

recharge the Power Pak.

A yellow LED indicates a 50 to 75% charge. The Power Pak may be 

b. 

used but should be recharged as soon as possible.

A green LED indicates the internal battery is fully charged.

c. 

CHARGING THE INTERNAL BATTERY WITH PLUG-IN WALL CHARGER

4. 

After removing the Power Pak from the carton, charge it for a minimum of 

4.1 

eight hours before using, even if the green charged LED glows. 

NOTE:

 The ON/OFF switch should be in the OFF position to recharge the 

internal battery. 

To charge, plug a wall charger into the socket on the front of the Power 

4.2 

Pak.
Plug the wall charger into 120V electrical wall outlet. 

4.3 

The red CHARGING LED will glow indicating charging.

4.4 

The green led will glow when the battery has reached full charge. This 

4.5 

could take up to 72 hours due to age and condition of the battery. The 

charger will automatically drop into a float mode and maintain the battery 

at full charge without damaging the battery. 
Charge the Power Pak as soon as possible after each use.

4.6 

OPERATING INSTRUCTIONS 

5. 

USING THE INVERTER

5.1 

It is important to know the continuous wattage of the device you plan to 

use with the inverter. The Power Pak must be used with devices drawing 

400 watts or less. If the wattage is not marked on the device, an estimate 

can be made by multiplying the AC input current (Amps) by the AC voltage 

(120V). 
Devices like TVs, fans or electric motors require additional power to start 

(commonly known as the “starting or peak power”). The Power Pak can 

supply a momentary surge in wattage; however even devices rated less 

than the maximum 400 watts can exceed the inverter’s surge capability 

and cause an automatic overload shutdown.
Make sure the device you are using is compatible with a modified sine 

wave inverter.

CAUTION: 

Always run a test to establish whether the inverter will operate 

Summary of Contents for Power Pak JO-1800

Page 1: ...Model JO 1800 POWER PAK 12V DC POWER SOURCE 400 WATT INVERTER OWNER S MANUAL 00 99 000899 1008 2 READ ENTIRE MANUAL BEFORE USING THIS PRODUCT IMPORTANT CHARGE IMMEDIATELY AFTER PURCHASE...

Page 2: ......

Page 3: ...Power Pak the device being 1 5 operated or any other surfaces that may come in contact with any power source are wet Water and many other liquids can conduct electricity which may lead to serious inju...

Page 4: ...charging 4 4 The green LED will glow when the battery has reached full charge This 4 5 could take up to 72 hours due to age and condition of the battery The charger will automatically drop into a flo...

Page 5: ...r switch ON I OFF 0 and ON I again in quick succession If this procedure is not successful it is likely that the Power Pak does not have the required capacity to operate the device in ques tion Charge...

Page 6: ...ay vary Times are based on the internal battery being fully charged The DC accessory outlet has a 15 amp automatic overload protection circuit breaker If an overload occurs unplug remove accessory and...

Page 7: ...C Capacity 18 Ah DC Power Outlet Max Continuous Load 15A Dimensions H x W x D 11 5 x 9 5 x 6 5 Product Weight 14 25 lbs Maximum Continuous Power 400 Watts Surge Capacity Output Wattage 800 Watts No Lo...

Page 8: ...cluding but not limited to express implied or statutory warranties including without limitation any implied war ranty of merchantability or implied warranty of fitness for a particular purpose Further...

Page 9: ...7 Modelo JO 1800 POWER PAK Fuente de Poder para 12V DC Inversor de Corriente de 400 WATT MANUAL DEL usuario LEA TODO EL MANUAL ANTES DE USAR ESTE PRODUCTO...

Page 10: ...n entrar en contacto con alguna fuente de electricidad est n mojadas El agua y muchos otros l quidos pueden conducir electricidad que puede producir severas lesiones No coloque la Power Pak en o cerca...

Page 11: ...bater a haya alcanzado su carga 4 5 total Esto puede llegar a tomar hasta 72 horas dependiendo de la edad y condici n de la bater a El cargador cambiar autom ticamente a un la funci n de modo flotante...

Page 12: ...rsor oprima el interruptor de la posici n ON FF repetidas veces Si este procedimiento no funciona se podr a entender que la Power Pak no tiene la capacidad requerida para operar el aparato en cuesti n...

Page 13: ...er a interna est cargada en tu totalidad El enchufe de 12V tiene un sistema autom tico de protecci n de 15 Amp de corta circuito Si hay una sobrecarga desconecte el accesorio y el cortador autom ticam...

Page 14: ...Salida de Corriente Carga M xima Continua 15A por salida Dimensiones Alto x Ancho x Prof 11 5 x 9 5 x 6 5 Peso 14 25 lbs Potencia M xima Continua 400 Watts Capacidad de inicio pico de arranque 800 Wat...

Page 15: ...no sea el Fabricante o si es revendida a trav s de un vendedor no autorizado El Fabricante no emite ni admite ninguna otra garant a que esta pero no limita a implicar garant as legales incluyendo las...

Page 16: ...14...

Reviews: