33
EN
• With a single press (rapid) of the grinding start key
(5)
, dispensing the coffee and
countdown until zero are activated.
• Once dispensing is completed, the grinding time returns to set value.
• The double dose counter
(21)
is increased of 1.
• By pressing the increasing key
(11)
and decreasing one
(10)
the
dispensing time of the selected dose is increased or decreased of more or less 5
hundredths of a second.
• If the increasing key
(11)
or decreasing one
(10)
is held down, the time is
increased or decreased by pressing time of the button.
You can stop the automatic dispensing before it is finished the grinding
time. During dispensing with the filter press the start button of the grinding
(5) to stop dispensing:
•
Press the Start button grinding (5) to resume delivery for the remaining time;
•
Press the dose button (blinking) to stop dispensing. The grinding time returns
to the set value.
5.5.3
CONTINUOUS DISPENSING MODE ACTIVATION
Pressing with the filter holder the start grinding button
(5)
for more than 0.5 seconds,
you start dispensing in continuous mode.
During the continuous delivery you turn on both dose buttons
(12)
and
(13)
and shows the symbol
(15)
on the display.
The last delivery to the start of the button pressing time grinding
(5)
.
When you release the start grinding button
(5)
, ending the continuous delivery and the
machine returns to the automatic mode of dose selection.
5.5.4
PARTIAL DOSE COUNTER ZEROING
By pressing both keys
(11)
and
(10)
for more than 5 seconds, both dose
counters are reset
(18-21)
.
5.5.5
FUNCTION BLOCK
Pressing both buttons
(11)
and
(10)
to their release, locks the adjustment of
the dose delivery time. Furthermore, display shows the symbol
(19)
. Press again
both buttons
(11)
and
(10)
to unlock.