background image

 San Diego 

|

 Luxembourg 

|

 Dubai 

|

 Ningbo | Singapore

FlowPath

 Control

Owner's Manual

ALL PURPOSE-BATTERY VENTILATOR

EX150Li

Summary of Contents for Ramfan EX150Li

Page 1: ...San Diego Luxembourg Dubai Ningbo Singapore FlowPath Control Owner s Manual ALL PURPOSE BATTERY VENTILATOR EX150Li...

Page 2: ...odes 10 AC Operation 10 DC Operation 10 Connection of Battery Pack 10 11 Battery Operation Procedures 12 13 Run Time 13 Charging Procedure 14 The Fuel Gauge 15 Status Indicator Lights 16 Battery Pack...

Page 3: ...ions and all pertinent product information After you have become familiar with this manual we recommend that you keep a copy for future use All the information found in this manual is subject to chang...

Page 4: ...not intended for operation in explosive atmospheres Wear ear protection when close by Keep body parts and loose objects away from in take of ventilator Do not move ventilator while in operation Operat...

Page 5: ...normal horizontal and hanging positions The ventilator can be tilted from 0 30 within the frame in PPV mode The motor controller and batteries are water resistant IP66 rated The motor is a variable s...

Page 6: ...n DC Max 30 min AC Unlimited AC Input Multiple plug options available Battery System 52V Lithium Ion 832Wh 16Ah IP Rating Motor Battery System Controller IP66 IP66 IP66 Weight 2 packs Without Battery...

Page 7: ...low 4 Speed Control Controlled operation from 0 to full speed 5 Battery Status LED Lights 6 Ventilator Status LED Lights See table below for details MAX MAX L R BAT FAULT AC PWR DC PWR DC MAX FAULT NO...

Page 8: ...sary to use a power cord with another plug standard order the power cord that matches the electrical requirements of the country or area The physical adapter for the outlet is interchangeable for use...

Page 9: ...on unscrew the tilt adjustment knob and adjust it at the desired angle upwards and then lock it in position by tightening the knob The shroud can pivot upwards to a range of 30 30 Tilting Angle 30 Pul...

Page 10: ...or 240V AC 50 Hz without manual adjustments by the user Operation out of these limits can damage electrical components and will void the warranty 1 Connect the fan to an AC power source 2 Status LED...

Page 11: ...11 Example of label placed on batter base ALIGN BATTERY EX150Li ALIGN BATTERY EX50Li LB9113 EX150 ALIGN BATTE EX50L LB9113 Gently pull up the yellow handle to remove the battery from the holder...

Page 12: ...become discharged the other battery will provide power to operate the system When using dual batteries it s important that both batteries be of the same charge level and ideally of the same age and co...

Page 13: ...us LED Light will flash white for the status Remember that this will only work when 2 batteries are connected to the ventilator and when it is operating exclusively on DC current source battery The ve...

Page 14: ...attery Status Indicator lights turning green and all the five Fuel Gauge lights on the battery turning red Should the Speed Control be turned counterclockwise on during the charge charging will stop a...

Page 15: ...ely five seconds The numbers represent each LED and the grid is how they re laid out 1 2 3 4 5 Fuel Gauge Lights Diagnosis Solution LEDs 1 5 Red Solid Remaining Run Time Continue Working LED 1 Red Fla...

Page 16: ...ng on battery power the estimated remaining battery time is shown If all the lights flash red this indicates that the battery has failed and the battery must be replaced Battery Pack Protection To pro...

Page 17: ...requirement the ventilator is equipped with a built in Transport Mode function When this function is activated the motor automatically runs a very low rpm to let the battery discharges until it reache...

Page 18: ...charge on Li ion is fine There is no memory and the battery does not need periodic full discharge cycles to prolong life Battery s will need to be replaced as they age Keep the ventilator attached to...

Page 19: ...spare parts call Euramco Group 1 619 670 9590 or theteam euramco com Always dispose of your battery pack according to federal state and local regulations Even discharged batteries contain some energy...

Page 20: ...es accessories RAMFAN s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow These PPV blowers have proven to be...

Page 21: ...bstances Standards to which this Conformity is Declared BS EN ISO 13857 2008 Safety Distances ISO 12100 2010 Safety Machinery BS EN 61000 6 2 2005 EMC Immunity for Industrial Environments BS EN 61000...

Page 22: ......

Page 23: ......

Page 24: ...heteam euramcosafety com LUXEMBOURG 1 Rue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590...

Reviews: