SD20-G Series
55
4.1.3 Typical main circuit wiring examples
For 220V servo drive
Alarm relay
RLY normally-
open contact
Contactor KM1
Normally-open
contact
KM1
L1
L2
L3
L1C
L2C
B2
B3
N+
N-
B1
QF circuit breaker
U
V
W
Three-phase AC
220V power supply
*
PE
M
PG
ALM+
ALM-
+24V
0V
Alarm relay
RLY
CN1
CN2
CN3
Contactor
KM1 coil
Manual power on
External resistor
Servo motor
P
E
FIL filter
Manual power off
Fig 4-1-4 Typical main circuit wiring of 220V servo drive
Note:
1. Built-in resistor is default and B2 and B3 terminal is short-circuit. If external resistor is used, please remove the
short cable between B2 and B3, and then connect external resistor between B1 and B2.
2. RLY
:
Alarm-signal output relay.
3. KM1: Contactor, connect or disconnect to main circuit power supply through manual switch.
4. If absolute encoder multi-turn function is adopted, please install battery.
Note: please connect an emergency stop circuit to main circuit so that servodrive can stop and power
off immediately in case accident occurs.
Summary of Contents for SD20-G Series
Page 35: ...SD20 G Series 35 M3 structure Fig 3 1 5 Servo drive structure 3...
Page 36: ...SD20 G Series 36 ML3 structure 118 5 5 7 5 93 297 8 223 118 93 0 5 12 5 7 5 4 M4...
Page 38: ...SD20 G Series 38 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5...
Page 39: ...SD20 G Series 39 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6...
Page 40: ...SD20 G Series 40 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7...
Page 182: ...SD20 G Series 182 Fig 6 4 44SD20E Cam internal frameworkdiagram...