Euphonix Max Air Installation Guide
Max Air Components
74
Figure 3-34
Stagebox configuration #1
IO95 Modular I/O Frame
: The IO95 frame is a double-sided 3RU frame identical
to the IO93 frame, except for an audio buss modification. This modification con-
sists of separating audio busses on the rear-plane to provide four “positions” to be
used as local-side interfaces for redundant MADI-over-fiber stageboxes. Each of
these positions may be fitted with an MM936 MADI In/Out (redundant fiber) and
an MM934 MADI In/Out (coax) to act as redundant MADI-over-fiber-to-MADI
coax converters. The MM936 configuration is done via the FC972 Remote also in-
stalled in the frame. Sync is handled by the SY983 Sync module. Other slots may
be used for additional I/O as these audio busses have no interaction with the four in-
terface positions. Sync and remote modules are shared thoughout the entire frame.
The frame PSUs provide 12 amps@5vDC. See figure 3-35.
Figure 3-35
Local-Side Interface configuration #1