EUCHNER NM VZ Series Operating Instructions Manual Download Page 4

4

Operating Instructions

Safety Switch NM..VZ

Correct use

Safety switches series NM are interlocking devices 

without guard locking (separate actuator). The ac-

tuator has a low coding level. In combination with 

a movable safety guard and the machine control, 

this safety component prevents dangerous machine 

functions from occurring while the safety guard is 

open. A stop command is triggered if the safety 

guard is opened during the dangerous machine 

function.
This means:

 

f

Starting commands that cause a dangerous ma-

chine function must become active only when the 

safety guard is closed.

 

f

Opening the safety guard triggers a stop com-

mand.

 

f

Closing a safety guard must not cause automatic 

starting of a dangerous machine function. A 

separate start command must be issued. For 

exceptions, refer to EN  ISO  12100 or relevant 

C-standards.

Before the device is used, a risk assessment must 

be performed on the machine, e.g. in accordance 

with the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design

 

f

EN  ISO  12100, Safety of machinery – General 

principles for design – Risk assessment and risk 

reduction

 

f

IEC  62061, Safety of machinery – Functional 

safety of safety-related electrical, electronic and 

programmable electronic control systems

Correct use includes observing the relevant require-

ments for installation and operation, particularly 

based on the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design

 

f

EN ISO 14119, Safety of machinery – Interlocking 

devices associated with guards – Principles for 

design and selection

 

f

EN  60204-1, Safety of machinery – Electrical 

equipment of machines – Part 1: General re-

quirements

Important!

 

f

The user is responsible for the proper integration 

of the device into a safe overall system. For this 

purpose, the overall system must be validated, 

e.g. in accordance with EN ISO 13849-2.

 

f

If the simplified method according to section 6.3 

of EN ISO 13849-1:2015 is used for determining 

the Performance Level (PL), the PL might be re-

duced if several devices are connected in series.

 

f

Logical series connection of safe contacts is 

possible up to PL  d in certain circumstances. 

More information about this is available in 

ISO TR 24119.

 

f

If a product data sheet is included with the prod-

uct, the information on the data sheet applies 

in case of discrepancies with the operating 

instructions.

Safety precautions

 WARNING

Danger to life due to improper installation or due 

to bypassing (tampering). Safety components 

perform a personal protection function.

 

f

Safety components must not be bypassed, 

turned away, removed or otherwise rendered 

ineffective. On this topic pay attention in partic-

ular to the measures for reducing the possibility 

of bypassing according to EN ISO 14119:2013, 

section 7.

 

f

The switching operation must be triggered only 

by actuators designated for this purpose.

 

f

Prevent bypassing by means of replacement 

actuators. For this purpose, restrict access to 

actuators and to keys for releases, for example.

 

f

Mounting, electrical connection and setup only 

by authorized personnel possessing special 

knowledge about handling safety components.

Function

The safety switch monitors the position of movable 

safety guards. The switching contacts are actuated 

on the insertion/removal of the actuator. 

Switching states

The detailed switching states for your switch can be 

found in Figure 3. All available switching elements 

are described there.
Safety guard open
The safety contacts   are open.
Safety guard closed
The safety contacts   are closed.

Selection of the actuator

NOTICE

Damage to the device due to unsuitable actuator. 

Make sure to select the correct actuator.
Additionally pay attention to the door radius and 

the fastening options (see Figure 5).

Mounting

NOTICE

Device damage due to improper mounting and 

unsuitable ambient conditions

 

f

Safety switches and actuators must not be used 

as an end stop.

 

f

Observe EN ISO 14119:2013, sections 5.2 and 

5.3, for information about fastening the safety 

switch and the actuator.

 

f

Observe EN  ISO  14119:2013, section 7, for 

information about reducing the possibilities for 

bypassing an interlocking device.

 

f

Protect the switch head against damage as well 

as penetrating foreign objects such as swarf, 

sand and blasting shot, etc.

Changing the actuating direction

Figure 1:  Changing the actuating direction

1.  Remove the screws from the actuating head.
2.  Set the required direction.
3.  Tighten the screws with a torque of 0.8 Nm.
4.  Cover the unused actuating slot with the en-

closed slot cover.

Electrical connection

 WARNING

Loss of the safety function due to incorrect 

connection.

 

f

Use only safe contacts ( ) for safety functions.

 

f

When choosing the insulation material and 

wire for the connections, pay attention to the 

required temperature resistance and the max. 

mechanical load!

Figure 2:  Opening the safety switch

Use of the safety switch as an interlocking 

device for personnel protection
At least one contact   must be used. It signals 

the guard locking state (for terminal assignment, 

see Figure 3).
The following information applies to devices 

with plug connector:

 

f

Check that the plug connector is sealed.

The following information applies to devices 

with cable entry:
1.  Use a suitable tool to open the desired inser-

tion opening.

2.  Fit the cable gland with the appropriate degree 

of protection.

3.  Connect and tighten the terminals with 0.5 Nm 

(for terminal assignment, see Figure 3).

4.  Check that the cable entry is sealed.
5.  Close the switch cover and screw in place 

(tightening torque 0.8 Nm).

Function test

 WARNING

Fatal injury due to faults during the function test.

 

f

Before carrying out the function test, make sure 

that there are no persons in the danger area.

 

f

Observe the valid accident prevention regula-

tions.

Check the device for correct function after installa-

tion and after every fault.
Proceed as follows:
Mechanical function test
The actuator must slide easily into the actuating 

head. Close the safety guard several times to check 

the function.
Electrical function test
1.  Switch on operating voltage.
2.  Close all safety guards.

¨

¨

The machine must not start automatically.

3.  Start the machine function.
4.  Open the safety guard.

¨

¨

The machine must switch off and it must not be 

possible to start it as long as the safety guard 

is open.

Repeat steps 2 - 4 for each safety guard.

Summary of Contents for NM VZ Series

Page 1: ...achperso nal welches über spezielle Kenntnisse im Umgang mit Sicherheitsbauteilen verfügt Funktion Der Sicherheitsschalter überwacht die Stellung von beweglichen trennenden Schutzeinrichtungen Beim Einführen Herausziehen des Betätigers werden die Schaltkontakte betätigt Schaltzustände Die detaillierten Schaltzustände für Ihren Schalter finden Sie in Bild 3 Dort sind alle verfügbaren Schal telement...

Page 2: ...ng ist Bestandteil der Be triebsanleitung und liegt dem Gerät als separates Blatt bei Die originale EU Konformitätserklärung finden Sie auch unter www euchner de Service Wenden Sie sich im Servicefall an EUCHNER GmbH Co KG Kohlhammerstraße 16 D 70771 Leinfelden Echterdingen Servicetelefon 49 711 7597 500 Fax 49 711 753316 E Mail support euchner de Internet www euchner de v h 21 13 21 31 11 21 31 3...

Page 3: ...A 12 5 7 3 Standar d 0 8 B 20 4 20 4 0 4 C M 0 8Nm D M 0 8Nm A B A Eintauchtiefe Eintauchtiefe fixierte Positionierung für Sicherheitsanwen dungen M5 B 18 16 5 25 17 Ø 4 2 M16x1 5 Ø 5 31 1 5 36 5 12 5 25 32 82 3 A 12 5 7 3 Standar d 0 8 B 20 4 20 4 0 4 A C M 0 8Nm D A B M 0 8Nm NM01VZA NM C2069 Eintauchtiefe Eintauchtiefe fixierte Positionierung für Sicherheitsanwen dungen M5 R 150 R 200 R 2 0 0 B...

Page 4: ...or example f f Mounting electrical connection and setup only by authorized personnel possessing special knowledge about handling safety components Function The safety switch monitors the position of movable safety guards The switching contacts are actuated on the insertion removal of the actuator Switching states The detailed switching states for your switch can be found in Figure 3 All available ...

Page 5: ...aration of conformity can also be found at www euchner com Service If service support is required please contact EUCHNER GmbH Co KG Kohlhammerstraße 16 D 70771 Leinfelden Echterdingen Service telephone 49 711 7597 500 Fax 49 711 753316 E mail support euchner de Internet www euchner de v h 21 13 21 31 11 21 31 31 21 13 21 22 14 22 32 12 22 32 32 22 14 22 21 31 21 13 31 21 11 21 31 21 13 22 32 22 14...

Page 6: ... 12 5 25 32 113 3 16 M 0 8Nm A 12 5 7 3 Standar d 0 8 B 20 4 20 4 0 4 C M 0 8Nm D M 0 8Nm A B A Insertion depth Insertion depth Fixed positioning for safety related applications M5 B 18 16 5 25 17 Ø 4 2 M16x1 5 Ø 5 31 1 5 36 5 12 5 25 32 82 3 A 12 5 7 3 Standar d 0 8 B 20 4 20 4 0 4 A C M 0 8Nm D A B M 0 8Nm NM01VZA NM C2069 Insertion depth Insertion depth Fixed positioning for safety related appl...

Reviews: