9.2.2.18. Testable safety device (TESTABLE SAFETY DEVICE)
Using the TESTABLE SAFETY DEVICE function block the input status of a single-channel or a dual-channel safety sensor
(both normally closed contacts and normally open contacts) is checked. Refer to the following tables for the sensor type
and behavior:
Figure 113: Testable safety device
Single normally closed contact
Figure 114: NC
IN
OUT
0
0
1
1
Table 61: Status table NC
Single normally open contact
Figure 115: NO
IN
OUT
0
0
1
1
Table 62: Status table NO
Double NC
Figure 116: Dual-channel NC
IN1
IN2
OUT
Contemporaneity error *
0
0
0
-
0
1
0
X
1
0
0
X
1
1
1
X
Table 63: Status table dual-channel NC
Double NC-NO
Figure 117: Dual-channel NC-NO
IN1
IN2
OUT
Contemporaneity error *
0
0
0
X
0
1
0
-
1
0
1
-
1
1
0
X
Table 64: Status table dual-channel NC-NO
* Contemporaneity error = max. time between the switching of the individual contacts has been exceeded.