Operating Instructions Safety Systems
MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
26
(translation of the original operating instructions) 2500233-04-10/21
10. Changing the door hinge position
10.1. Changing the interlocking/locking module to a different door hinge position
To change the interlocking/locking module for doors with a different door hinge position, the module only needs to be rotated
by 180°. Submodules installed in the module can also be rotated by 180° (see section
9.1. Replacing modules on page 23
10.2. Changing actuating direction of the handle module
(here: from right to left)
Important!
It is possible to make this change only when the bolt tongue is not extended and an escape release
is not yet mounted.
In the delivery state, the handle module is set either for doors hinged on the right or for doors hinged on the left.
Based on the example of a handle module for doors hinged on the right this means:
Ì
The guard opens by pressing down the door handle.
Ì
The system is mounted the other way up for doors hinged on the left. In other words, the guard opens by pressing up
the door handle (see
). For this reason the actuating direction of the door handle must be changed (see
(Similarly on handle modules for doors hinged on the left)
CLOSED
OPEN
1
1
Press door handle up.
Fig. 13: Changing actuating direction, step
1
3
2
2
Unscrew locking screws.
3
Push cover aside.
Fig. 14: Changing actuating direction, steps
2
and
3