8. Mounting
WARNING
Mounting must be performed only by authorized personnel.
With two-wing hinged doors, one of the two door wings additionally must be latched mechanically.
Use a rod latch (Item) or a double-door lock (Bosch Rexroth) for this purpose, for example.
Important!
Ì
If installed flush, the switching distance changes as a function of the installation depth and the
safety guard material.
Interlocking
module
Handle module
Handle module
Interlocking
module
Surface mounting
Flush mounting
Operating distance
Operating distance
Tip!
Ì
You will find an animation on the mounting process at www.euchner.de.
Ì
The color and labeling of pushbuttons and indicators can be modified.
For mounting steps, see
Figure 7
and
Figure 8
to
Figure 13
.
Install system so that inspection and maintenance are possible.