2119167-06-10/20 (Translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
EN
15.2. System status table MGB-AR
Operating mode
Safety inputs FI1A
and FI1B
Door position
Position of the bolt
tongue
Guard locking
Safety outputs FO1A
and FO1B
Door monitoring output
(OD)
Bolt tongue monitoring
output (OT)
Guard lock monitoring
output (OL)
Diagnostics monitoring
output (OI)
LED indicator
State
Power (green)
STATE (green)
DIA (red)
Lock (yellow)
Self-test
X
X
X
X
OFF
OFF
OFF
OFF
OFF
5 Hz
Self-test after power-up
Normal oper
-
ation
X
open
not inser
ted
OFF
OFF
OFF
OFF
OFF
OFF
long OFF
,
shor
t ON
Normal operation, door open
X
closed
not inser
ted
OFF
OFF
ON
OFF
OFF
OFF
long ON, shor
t OFF
Normal operation, door closed
OFF
closed
inser
ted
OFF
OFF
ON
ON
OFF
OFF
long ON, shor
t OFF
long ON, shor
t OFF
Normal operation, door closed, bolt tongue inser
ted, safety inputs FI1A/FI1B OFF
ON
closed
inser
ted
OFF
OFF
ON
ON
OFF
OFF
long ON, shor
t OFF
long ON, shor
t OFF
W
ith active guar
d lock monitoring:
normal operation, door closed, bolt tongue inser
ted. Safety inputs
FI1A/FI1B ar
e ON. Safety outputs FO1A and FO1B
ar
e OFF
ON
W
ith inactive guar
d lock monitoring:
normal operation, door closed, bolt tongue inser
ted. Safety inputs
FI1A/FI1B ar
e ON. Safety outputs FO1A and FO1B ar
e ON
OFF
closed
inser
ted
ON
OFF
ON
ON
ON
OFF
long ON, shor
t OFF
Operation in an AR chain:
normal operation, door closed and locked. Safety outputs on the pr
evious
device OFF
ON
closed
inser
ted
ON
ON
ON
ON
ON
OFF
Operation as separate device:
normal operation, door closed and locked
Operation in an AR chain:
normal operation, door closed and locked. Safety outputs on the pr
evious
device ON
Teach-in standby
(only for MGB unicode)
X
open
not inser
ted
OFF
OFF
OFF
OFF
OFF
OFF
3 x
Door open; device is r
eady for teach-in of another handle module (only 3 min. after Power UP)
Setup
(only for MGB unicode)
X
closed
inser
ted
ON
OFF
OFF
OFF
OFF
OFF
1 Hz
Tip for teach-in operation: to pr
event the interruption of teach-in operations, close door and switch on guar
d
locking.
X
X
X
X
OFF
OFF
OFF
OFF
OFF
Positive acknowledgment after completion of teach-in operation
Diagnostics
X
X
X
X
OFF
OFF
OFF
OFF
ON
1 x
Err
or during teach-in/configuration or invalid DIP switch setting
err
one
-
ous
X
X
X
OFF
OFF
OFF
OFF
ON
2 x
FI1A/FI1B input err
or (e.g. missing test pulses, illogical switching state fr
om pr
evious switch)
X
X
X
X
OFF
X
X
X
OFF
3 x
Handle module r
ead err
or (e.g. err
or in code)
X
X
X
X
OFF
OFF
OFF
OFF
ON
4 x
Output fault (e.g. shor
t cir
cuit, loss of switching capability) or shor
t cir
cuit at the outputs
X
X
X
X
X
OFF
OFF
OFF
ON
Internal fault (e.g. component faulty
, data err
or)
X
X
X
X
OFF
OFF
OFF
OFF
ON
1 x
Signal sequence err
oneous (e.g. br
oken bolt tongue).
W
ith active r
elease monitoring: escape r
elease or auxiliary r
elease was actuated
X
X
X
X
X
OFF
OFF
OFF
ON
2 x
Contr
ol inputs IMP1, IMP2, IMM invalid; switch contr
ol inputs of
f for min. ½ s and switch on again to r
eset
After r
emedying the cause, use the r
eset function (see chapter
roubleshooting and assistance on page 41
) or briefly disconnect the power supply
. Please contact the manufactur
er if the fault could not be r
eset after r
estar
ting.
Impor
tant
: If you do not find the displayed device status in the system status table, this indicates an internal device fault. In this case, you should contact the manufactur
er
.