13.13. PROFISAFE errors
Err
or code
Err
or designation
Meaning
Err
or category
Err
or behavior
Tr
oubleshooting
Corr
esponding err
or/
status bit
LED displays
Bus module
LINK 1 / LINK 2
ACT 1 / ACT 2
SF
BF
DIA
US1
MAINT
PS
0x0150
F_DEST_
ADDR
Erroneous
safety
destination
address
Param-
eter
setting
error
Latch-
ing
The PROFIsafe address
set on the device does not
match the address set in the
configuration tool for your
control system. Either modify
the DIP switch setting or
change the information in the
parameter F_dest_adr.
BM_E_G
1x
0x0151
F_DEST_
ADDR
Safety
destination
address invalid
Param-
eter
setting
error
Latch-
ing
The PROFIsafe address set
in the configuration tool for
your control system has an
impermissible value. Check the
parameter setting.
0x0152
F_
SOURCE_
ADDR
Safety source
address invalid
Param-
eter
setting
error
Latch-
ing
The PROFIsafe source address
set in the configuration tool
for your control system has an
impermissible value. Check the
parameter setting.
0x0153
F_WD_
TIME
Watchdog
timer value is
0 ms
Param-
eter
setting
error
Reset-
table
The value for the watchdog
timer set in the configuration
tool for your control system
has an impermissible value.
Check the parameter setting.
0x0154
F_SIL
Parameter
F_SIL exceeds
SIL for the
specific device
application
Param-
eter
setting
error
Reset-
table
The value for F_SIL set in
the configuration tool for
your control system has an
incorrect value. Check the
parameter setting.
0x0155
F_CRC_
Length
Parameter
F_CRC_
LENGTH does
not correspond
to the values
generated
The value for the length of the
CRC set in the configuration
tool for your control system
has an incorrect value. Check
the parameter setting.
0x0156
F_Version
Version for F
parameter set
incorrectly
Param-
eter
setting
error
Reset-
table
An incorrect version or
an invalid F_Version has
been detected. Check the
parameter setting.
0x0157
F_CRC1
CRC1 error
Param-
eter
setting
error
Reset-
table
The CRC value calculated does
not match the value in the
GSDML file. There may be an
incorrect value in the GSDML
file or incorrect transmission
due to interference (e.g. EMC
problems)
0x0158
Device
specific
diagnosis
informa-
tion
Device-specific
fault
Information that a device-
specific fault has occurred.
See error codes from chapter
13.5. General errors on page
39ff.
0x0159
Watchdog Time
iParameter
saving
exceeded
0x0162
F_Block_ID not
supported
Param-
eter
setting
error
Reset-
table
Check the parameters and
correct them. Then load the
parameters into the assembly
again.