15.2. Function and time diagrams
15.2.1. Time diagram for automatic start
Continuous auto start
Ì
Permanently High signal at S21
S1
S2
Enable
K1
K2
S10/S21
auto
Figure 9:
Time diagram for automatic start
15.2.2. Time diagram for manual, monitored start
Ì
Start on falling edge at S21
S1
S2
S11/S21
Enable
K1
K2
man
Figure 10: Time diagram for manual, monitored start
Autostart pulse
Ì
Start on rising edge at S21
S1
S2
Enable
K1
K2
S10/S21
auto
Figure 11: Time diagram for automatic start
Time diagram for enable principle
S1
S2
S11/S21
Enable
K1
K2
man
L+
A1
Figure 12: Time diagram for enable principle
Key:
S1/S2
Sensor
circuits
S10/S21 auto
Start circuit for automatic start
S11/S21 man
Start circuit for manual, monitored start
K1/K2
Output
circuits
L+
IO-Link
supply
A1
Power
supply
Enable
Enable signal via IO-Link