15. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
15.1. Safety relay ESM-CB
Ì
Diagnostic data via IO-Link in combination with BR safety switches
Ì
Short circuit detection
Ì
Plug-in spring terminals
Ì
17.5 mm housing width
Dimension drawing
A1
C/Q
13
24
14
23
STATE2
STATE1
PWR
OM
ES
M-
CB
S34
13 14 23
S32
S10
S11 S12 S14
S21
A2
A1
ID/C
C/Q L+ L-
24
IO-Link
K1/K2
DIA
17,6
ca
.1
12
113,6
99
Safety contacts
Possible signaling devices
Ì
Emergency stop pushbuttons
Ì
Safety door interlocks
Ì
Light grids
Contact type
Ì
Two sensor circuits
Ì
Two non-time-delayed safety contacts
Ì
One digital monitoring output
Ì
IO-Link interface
Ì
The safety contacts drop out without delay in accordance
with stop category 0 according to EN 60204-1.
Control
Ì
Single channel or dual channel
Ì
Automatic or manual, monitored start
Achievable safety integrity
Ì
Suitable up to category 4, PL e (EN ISO 13849-1), SIL-
CL 3 (EN 62061)
Approvals