Operating Instructions
Transponder-Coded Safety Switch CTP-AR
10
(translation of the original operating instructions) 2123041-08-01/21
The actuator cannot be pulled out of the switch and the guard is locked as long as the guard locking pin is extended.
If a voltage is applied to the guard locking solenoid, the guard locking pin is retracted and the actuator is released. The
guard can be opened.
6.7.
Guard locking on version CTP-L2
(guard locking actuated by power-ON and released by spring force)
Important!
Use as guard locking for personnel protection is possible only in special cases, after strict assessment
of the accident risk (see EN ISO 14119:2013, section 5.7.1)!
Activating guard locking:
apply voltage to the solenoid.
Releasing guard locking:
disconnect voltage from the solenoid.
The magnetically actuated guard locking operates in accordance with the open-circuit current principle. If the voltage is
interrupted at the solenoid, the guard locking is released and the guard can be opened directly.
The guard can be opened as long as no voltage is applied to the guard locking solenoid.
If a voltage is applied to the guard locking solenoid, the guard locking pin is held in the extended position and the guard is
locked.
6.8.
Switching states
The detailed switching states for your switch can be found in the system status table. All safety outputs, monitoring outputs
and display LEDs are described there.
Guard closed and locked
IMP
IMM
Guard closed and not locked
IMP
IMM
Guard open
IMP
IMM
Voltage on guard locking solenoid
CTP-L1
off
on
(irrelevant)
Voltage on guard locking solenoid
CTP-L2
on
off
(irrelevant)
Safety outputs FO1A and FO1B
on
off
off
Guard lock monitoring output OL
on
off
off
Door position monitoring output OD
on
on
off