15
2120545-05-08/18 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-I-AS2A-M-C04
EN
11.2. Technical data of actuator CES-A-BBN-C04
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PBT
Rubber-support material
NBR 80 ±5 Shore
Dimensions
42 x 25 x 18
mm
Weight
0.03
kg
Ambient temperature
- 40
-
+ 65
°C
Degree of protection
IP67/IP69K
Installation position
Active face opposite read head
Power supply
Inductive via read head
11.2.1. Dimension drawing
Active face
4,5
32
14
25
42
6
14,5
18
15,5
With rubber support
Rubber support
NOTICE
Ì
2 safety screws M4x20 included.
Ì
Rubber support included.
11.2.2. Switching distances
Operating distance for center offset m = 0
Approach direction
Parameter
Value
Unit
A
B
min.
typ.
max.
Switch-on distance
-
15
-
mm
Assured switch-on distance s
ao 1)
10
-
-
Switching hysteresis
1)
1
2
-
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) On approach in Z direction
Approach direction
Parameter
Value
Unit
C
D
min.
typ.
max.
Switch-on distance
-
11
-
mm
Assured switch-on distance s
ao
1)
6
-
-
Switching hysteresis
1)
1
2
-
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) On approach in x direction