2105360-10-07/19 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AP-C.2-…
EN
11.2.2. Switching distances
Operating distance for center offset m = 0
1)
Parameter
Value
Unit
min.
typ.
max.
Switch-on distance
-
15
-
mm
Assured switch-on distance s
ao
10
-
-
Switching hysteresis
1
2
-
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
40
60
1) The values apply to surface mounting of the actuator in metal.
11.2.3. Typical operating distance
(only in combination with actuator CES-A-BLN-…)
Z
-25
-30
X
10
5
15
20
-20
-25
-30
-40
-35
-15
-10
-5
-10
20
25
30
15
10
40
35
5
Y
15
20
25
5
-5
-15
30
10
-20
For a side approach direction for the actuator and safety switch, a minimum
distance of s = 6 mm must be maintained so that the operating distance of
the side lobes is not entered.
Figure 4:
Typical operating distance