System Manual Safety Switch CES-AH-C03-AH-SM
7
Montage
Caution!
Risk of damage to equipment as a result of incorrect installation. Safety switches
must not be used as a mechanical end stop.
Fit an additional end stop for the movable part of the safety guard.
Important!
From the assured switch-off distance S
ar
, the safety outputs are safely shut
down.
When mounting several safety switches, observe the stipulated minimum dis-
tance to avoid mutual interference.
min. 80mm
If the actuator is installed flush, the switching distance changes as a function
of the installation depth and the safety guard material.
Operating
distance
Actuator
Operating
distance
Actuator
Flush mounting
Surface maounting
Note the following points:
Actuator and safety switch must be easily accessible for inspection and re-
placement.
Actuator and safety switch must be fitted so that
the front faces are at the minimum switch-on distance 0.8 x S
ao
or closer
when the safety guard is closed (see section
Operating distances
). For a side
approach direction for the actuator a minimum distance must be maintained
so that the operating distance of the side lobes is not entered (see operating
distance for the actuator).
when the safety guard is open up to the distance S
ar
(assured switch-off dis-
tance), a hazard is excluded.
the actuator is positively mounted on the safety guard, e.g. by using the
safety screws included.