Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
50 x 50 x 20.2
mm
Weight
0.08
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP 67
Installation position
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA or CES-A-BCA on evaluation unit CES-A-AEA-…
Assured switch-off distance S
ar
-
-
47
mm
Operating distance for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
2
3
-
In combination with actuator CES-A-BQA on evaluation unit CES-A-AEA-…
Assured switch-off distance S
ar
-
-
60
mm
Operating distance with vertical approach direction
Center offset m = 0
1)
- Switch-on distance
-
23
-
- Assured switch-on distance S
ao
16
-
-
- Switching hysteresis
2
3
-
Operating distance with side approach direction
Distance in x direction = 10 mm
- Switch-on distance
-
28
-
- Assured switch-on distance S
ao
24
-
-
- Switching hysteresis
1
1.3
-
Connection
M8 plug connector (snap-action and screw terminals), 3-pin
Connection cable
-
-
25
m
1) These values apply to surface installation of the read head and the actuator.