27
2537377-01-05/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BP
EN
6. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
6.1.
Technical data for safety switch CTP-L1/2-BP
Parameter
Value
Unit
min.
typ.
max.
General
Material
- Switch head
- Switch housing
Die-cast zinc
Reinforced thermoplastic
Installation orientation
Any
Degree of protection
with plug connector M12
IP65/IP67/IP69/IP69K
with plug connector M23
IP65/IP67
(screwed tight with the related mating connector)
Safety class acc. to EN IEC 61558
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at U
B
= 24 V
-20
-
+55
°C
Actuator approach speed, max.
20
m/min
Actuating/extraction/retention force at 20 °C
10/20/20
N
Locking force F
max
1)
3,900
N
Locking force F
Zh
1)
acc. to EN ISO 14119
F
Zh
= F
max
/1.3 = 3,000
N
Weight
Approx. 0.42
kg
Connection (depending on version)
Plug connector M12, 5- and 8-pin / plug connector M23, 19-pin
Operating voltage U
B
(reverse polarity protected, regulated,
residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption I
UB
40
mA
The following applies to the approval acc. to UL
Operation only with UL Class 2 power supply or equivalent measures
Switching load acc. to UL
DC 24 V, class 2
External fuse (operating voltage U
B
)
2)
0.25
-
8
A
External fuse (solenoid operating voltage U
IMP
)
2)
0.5
-
8
A
Rated insulation voltage U
i
-
-
50
V
Rated impulse withstand voltage U
imp
-
-
0.5
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
8
11
s
Risk time for single device
-
-
260
ms
Risk time delay per device
5
ms
Turn-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test pulse duration
300
µs
Frequency band
120 … 130
kHz
Safety outputs
FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
FO1A
/U
FO1B
3)
V DC
HIGH U
FO1A
/U
FO1B
U
B
- 1.5
-
U
B
LOW U
FO1A
/U
FO1B
0
-
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN 60947-5-2
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
4)
0.5
Hz
Monitoring outputs OL, OI, OD
p-switching, short circuit-proof
Output voltage
0.8 x U
B
-
U
B
V DC
Max. load
-
-
50
mA
Solenoid
Solenoid operating voltage U
IMP
(reverse polarity protected,
regulated, residual ripple < 5%)
DC 24 V +10%/-15%
Solenoid current consumption I
IMP
400
mA
Connection rating
6
W
Duty cycle
100
%